Print Report | Back to Test Summary

Testing Report for 2019-05-20-19-3

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 213229 DEA: 050A0504 EFIS: 0500000007 QA Service Level: 1
DIST-CO-RTE-PM: 05-SB-1-15.6
Work Description: BRIDGE REPLACEMENT, RETAINING WALL AND FISH PASSAGE.
Location Description: SANTA BARBARA COUNTY NEAR LOMPOC AT SALSIPUEDES CREEK BRIDGE
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Lilian Bennetzen Structure Rep.: Hernandez, Bernardo

Sample Information

DIME Sample ID: 2019-05-20-19
TL Number from the TL Form: C760340
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Couplers
Sample Taken Date: 05/20/2019
Date that the sample was received by the laboratory/organization performing the testing: 05/28/2019
The quantity of what the sample constitutes: 4
A brief description of the sample: Bartec Couplers
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Nucor Dextra America

Material Information

Production or Authorization Testing: Production Testing
Service or Ultimate: Service
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Manufacturer: Nucor
Coupler Manufacturer: Dextra America
Intermediate Assembler or Fabricator: Unknown
Rebar Size: 9
Coupler Model: Bartec
Coating Standards: Uncoated
Shape of Rebar: Straight
Rebar Hoop Diameter: Unknown
Rebar Hoop Fabricator: Unknown
Coupler Component Heat/Lot Number(s): DL14106985
Rebar Heat Number(s): 3500004005
Rebar Size 2 :

Test Information

DIME Test ID: 2019-05-20-19-1
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Verified Date: 05/31/2019
Date Tested: 05/30/2019
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Service Splice
Additional Comments When Verified:

Submitted Test Results

Number of Samples 1
SampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
3C03#9/29mm109632896328Service SpliceBrian
Temperature 72 F
UTM 400KIP
Halo ID Small