Print Report | Back to Sample Detail

Sample Record for 2019-04-16-42

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214151 DEA: 080R0104 EFIS: 0812000007 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV--
Work Description:
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2019-04-16-42
TL Number from the TL Form: None
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Per Request
Type of Material: Soil
Sample Taken Date: 04/16/2019
Date that the sample was received by the laboratory/organization performing the testing: 04/18/2019
The quantity of what the sample constitutes: 1 Ziplock bag
A brief description of the sample: Soil
From where was the sample collected: Job Site
Laboratory sample identification: 8560
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Caltrans

Material Information

The fabricator's/manufacturer's product name for the sample: Unknown
The fabricator/manufacturer designation for the sample: Unknown
A detailed description of where the material sample was collected: Filed A-19-04, Sample Number S1
Where the material sample would have been placed if not sampled: Unknown

Test Results

Test 1 of 1

DIME Test ID: 2019-04-16-42-3
Test Method: CTM 203-February 2008: Mechanical Analysis of Soils
Verified Date: 05/30/2019
Date Tested: 04/26/2019
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test: Hydrometer Results: 1 hour 5%, 24 hours 3%
Test Result Compliance:
Additional Comments When Verified:
Cumulative percent passing the 3/8 in. sieve 81 %
Cumulative percent passing the #4 sieve 70 %
Cumulative percent passing the #8 sieve 59 %
Cumulative percent passing the #16 sieve 47 %
Cumulative percent passing the #30 sieve 37 %
Cumulative percent passing the #50 sieve 28 %
Cumulative percent passing the #100 sieve 21 %
Cumulative percent passing the #200 sieve 16 %

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
2019-04-16-42-1CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates05/30/2019Not scheduledNader Rashidi-GhaderCT D08 - Fontana Southern Regional Laboratory
2019-04-16-42-2CTM 203-February 2008: Mechanical Analysis of Soils05/30/2019Not scheduledNader Rashidi-GhaderCT D08 - Fontana Southern Regional Laboratory