What type of solution was used?
|
Sodium sulfate
|
What was the condition of the solution?
|
Freshly prepared
|
Mass of sample retained on the 3.5 in. sieve (before immersion)
|
100 grams
|
Mass of sample retained on the 3 in. sieve (before immersion)
|
95 grams
|
Mass of sample retained on the 2.5 in. sieve (before immersion)
|
90 grams
|
Mass of sample retained on the 2 in. sieve (before immersion)
|
80 grams
|
Mass of sample retained on the 1.5 in. sieve (before immersion)
|
75 grams
|
Mass of sample retained on the 1 in. sieve (before immersion)
|
70 grams
|
Mass of sample retained on the 3/4 in. sieve (before immersion)
|
60 grams
|
Mass of sample retained on the 1/2 in. sieve (before immersion)
|
50 grams
|
Mass of sample retained on the 3/8 in. sieve (before immersion)
|
40 grams
|
Mass of sample retained on the #4 sieve (before immersion)
|
30 grams
|
Split particles between 3/4 in and 1 1/2 in. (after immersion)
|
35
|
Crumbled particles between 3/4 in and 1 1/2 in. (after immersion)
|
20
|
Cracked particles between 3/4 in and 1 1/2 in. (after immersion)
|
10
|
Flaked between 3/4 in and 1 1/2 in. (after immersion)
|
20
|
Split particles between 1 1/2 in and 2 1/2 in. (after immersion)
|
25
|
Crumbled particles between 1 1/2 in and 2 1/2 in. (after immersion)
|
10
|
Cracked particles between 1 1/2 in and 2 1/2 in. (after immersion)
|
20
|
Flaked particles between 1 1/2 in and 2 1/2 in. (after immersion)
|
5
|
Split particles between 2 1/2 in and 3 in. (after immersion)
|
5
|
Crumbled particles between 2 1/2 in and 3 in. (after immersion)
|
10
|
Cracked particles between 2 1/2 in and 3 in. (after immersion)
|
25
|
Flaked particles between 2 1/2 in and 3 in. (after immersion)
|
20
|
Split particles between 3 in and 3 1/2 in. (after immersion)
|
30
|
Crumbled particles between 3 in and 3 1/2 in. (after immersion)
|
20
|
Cracked particles between 3 in and 3 1/2 in. (after immersion)
|
15
|
Flaked particles between 3 in and 3 1/2 in. (after immersion)
|
30
|
Split particles between 3 1/2 in and 4 in. (after immersion)
|
10
|
Crumbled particles between 3 1/2 in and 4 in. (after immersion)
|
5
|
Cracked particles between 3 1/2 in and 4 in. (after immersion)
|
20
|
Flaked particles between 3 1/2 in and 4 in. (after immersion)
|
10
|
Percent loss from sample retained on the 3.5 in. sieve
|
70 %
|
Percent loss from sample retained on the 3.0 in. sieve
|
79 %
|
Percent loss from sample retained on the 2 ½ in. x 1 ½ in. sieve
|
83 %
|
Percent loss from sample retained on the 1 ½ in. x ¾ in. sieve
|
94 %
|
Percent loss from sample retained on the ¾ in. x ⅜ in. sieve
|
98 %
|
Percent loss from sample retained on the ⅜ in. x No. 4 sieve
|
94 %
|
Percent loss from sample retained on the No. 4 x 8 sieve (coarse)
|
93 %
|
Percent of split particles between 3/4 in and 1 1/2 in.
|
28 %
|
Percent of crumbled particles between 3/4 in and 1 1/2 in.
|
16 %
|
Percent of cracked particles between 3/4 in and 1 1/2 in.
|
8 %
|
Percent of flaked particles between 3/4 in and 1 1/2 in.
|
16 %
|
Percent of split particles between 1 1/2 in and 2 1/2 in.
|
17 %
|
Percent of crumbled particles between 1 1/2 in and 2 1/2 in.
|
7 %
|
Percent of cracked particles between 1 1/2 in and 2 1/2 in.
|
14 %
|
Percent of flaked particles between 1 1/2 in and 2 1/2 in.
|
3 %
|
Percent of split particles between 2 1/2 in and 3 in.
|
6 %
|
Percent of crumbled particles between 2 1/2 in and 3 in.
|
13 %
|
Percent of cracked particles between 2 1/2 in and 3 in.
|
31 %
|
Percent of flaked particles between 2 1/2 in and 3 in.
|
25 %
|
Percent of split particles between 3 in and 3 1/2 in.
|
35 %
|
Percent of crumbled particles between 3 in and 3 1/2 in.
|
24 %
|
Percent of cracked particles between 3 in and 3 1/2 in.
|
18 %
|
Percent of flaked particles between 3 in and 3 1/2 in.
|
35 %
|
Percent of split particles between 3 1/2 in and 4 in.
|
11 %
|
Percent of crumbled particles between 3 1/2 in and 4 in.
|
6 %
|
Percent of cracked particles between 3 1/2 in and 4 in.
|
22 %
|
Percent of flaked particles between 3 1/2 in and 4 in.
|
11 %
|