Print Report | Back to Sample Detail

Sample Record for 2018-09-27-21

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 212910 DEA: 080K2914 EFIS: 0812000098 QA Service Level: 1
DIST-CO-RTE-PM: 08-SBD-10-30.9/33.3
Work Description: LANE REPLACEMENT
Location Description: SAN BERNARDINO COUNTY IN REDLANDS FROM ORANGE STREET UNDERCROSSING TO REDLANDS BLVD OFF-RAMP UNDERCROSSING
Contractor Name: SECURITY PAVING COMPANY, INC.
Contractor Address: 13170 TELFAIR AVENUE, SYLMAR, CA 91342
Resident Engineer: Nick Truong Structure Rep.: Ali El-Zaynab

Sample Information

DIME Sample ID: 2018-09-27-21
TL Number from the TL Form: 7
Sample Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Sample Organization Contact: 213-792-4794
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 09/27/2018
Date that the sample was received by the laboratory/organization performing the testing: 10/03/2018
The quantity of what the sample constitutes: 4
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification: 987-7
Structure unique identifier: LCB RS I 10 EB MAINLINE LANES 4 AND 5 AT STA 511 60
Structure name: LCB RS I 10 EB MAINLINE LANES 4 AND 5 AT STA 511 60
The fabricator/manufacturer/facility name: Security Paving company

Material Information

The concrete mix design number: 1555212
The truck number from where the sample was collected: NA
The batch plant ticket number from where the sample was collected: NA
Concrete batch plant: Unknown
The fabricator/manufacturer designation for the sample: SECURITY PAVING
A detailed description of where the material sample was collected: Chute
Where the material sample would have been placed if not sampled: LCB RS I 10 EB MAINLINE LANES 4 AND 5 AT STA 511 60
From Lot No.: Unknown
Bag Lot No.: Unknown

Test Results

Test 1 of 1

DIME Test ID: 2018-09-27-21-1
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Capped in accordance with ASTM C617/CTM521
Verified Date: 10/05/2018
Date Tested: 10/04/2018
Submitted By Organization: CT D08 - Fontana Southern Regional Laboratory
Organization Address: 13970 Victoria Street,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: jose.guzman@dot.ca.gov
Organization Phone: 9098293029
General Comments for this Test:
Test Result Compliance:
Additional Comments When Verified:
Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Cross sectional area of cylinder 1 28.18 in^2
Cross sectional area of cylinder 2 28.18 in^2
Capped in accordance with? ASTM C617/CTM521
Compressive strength (to nearest 10 psi) 5640 psi
Average diameter of cylinder 1 5.99 in
Average diameter of cylinder 2 5.99 in
Compressive strength of cylinder 1 5739.2 psi
Compressive strength of cylinder 2 5550.7 psi
Maximum load on cylinder 1 161730 lb
Maximum load on cylinder 2 156420 lb
Type of fracture pattern of cylinder 1 3
Type of fracture pattern of cylinder 2 3
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 7 days