Print Report | Back to Test Summary

Testing Report for 2018-07-23-11-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 211777 DEA: 04209504 EFIS: 0412000116 QA Service Level: 1
DIST-CO-RTE-PM: 04-MRN,SON-1-50.2/50.5,0.0/0.2
Work Description: REPLACE ESTERO BRIDGE AND REALIGN APPROACHING ROADWAY; Bridge No. 27-0121
Location Description: MARIN AND SONOMA COUNTIES NEAR VALLEY FORD FROM 0.4 MILE SOUTH OF ESTERO AMERICANO BRIDGE TO 0.2 MILE NORTH OF ESTERO AMERICANO BRIDGE
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Scott Hislop Structure Rep.: Law, Clifford

Sample Information

DIME Sample ID: 2018-07-23-11
TL Number from the TL Form: 161422
Sample Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Sample Organization Contact: (916) 227-7283
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 07/23/2018
Date that the sample was received by the laboratory/organization performing the testing:
The quantity of what the sample constitutes: cylinders
A brief description of the sample: 6x12 concrete cylinders
From where was the sample collected: Job Site
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Unknown

Material Information

The concrete mix design number: 4201A
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: not given
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: Back of Truck
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Information

DIME Test ID: 2018-07-23-11-1
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Verified Date: 09/04/2018
Date Tested: 09/04/2018
Submitted By Organization: CT HQ - Sacramento Concrete Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: larry.mccrum@dot.ca.gov
Organization Phone: (916) 227-7283
General Comments for this Test:
Additional Comments When Verified:

Submitted Test Results

Unit system used? US Units
Number of specimens 2
Test performed With no density determined
Capped in accordance with? ASTM C617/CTM521
Average diameter of cylinder 1 6.03 in
Average diameter of cylinder 2 6.03 in
Cross sectional area of cylinder 1 28.56 in^2
Cross sectional area of cylinder 2 28.56 in^2
Compressive strength (to nearest 10 psi) 4650 psi
Maximum load on cylinder 1 129354 lb
Maximum load on cylinder 2 136201 lb
Compressive strength of cylinder 1 4529.2 psi
Type of fracture pattern of cylinder 1 1
Compressive strength of cylinder 2 4768.9 psi
Type of fracture pattern of cylinder 2 1
Comment on any defect in either specimen or caps (Max 250 Characters) no data
Correction factor for cylinder 1 1
Correction factor for cylinder 2 1
Age of specimen 43 days
Age of specimen in hours no data