Testing Report for 2018-03-02-1-5

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 212731 DEA: 07318004 EFIS: 0715000280 QA Service Level: 1
DIST-CO-RTE-PM: 07-LA-10-22.3/28.2
Work Description: TREAT BRIDGE DECK, CLOSURE POUR AND REPLACE JOINT SEALS.
Location Description: LOS ANGELES COUNTY AT VARIOUS LOCATIONS FROM FREMONT AVENUE UNDERCROSSING TO RIO HONDO62
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Moe Izadpanah Structure Rep.: Man, Jennifer

Sample Information

DIME Sample ID: 2018-03-02-1
TL Number from the TL Form:
Sample Submitted By Organization: CT QASI - Los Angeles Field Laboratory
Sample Organization Contact: (858) 285-5797
Type of Sample: Quality Assurance
Type of Material: SMTL TM5 - Couplers
Sample Taken Date: 03/02/2018
Date that the sample was received by the laboratory/organization performing the testing: 04/05/2018
The quantity of what the sample constitutes: 3 lots
A brief description of the sample: Barsplice Double Barrel Zap Screwlok
From where was the sample collected: Fabricator
Laboratory sample identification:
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: DRS Rebar Inc

Material Information

Production or Authorization Testing: Production Testing
Service or Ultimate: Service
Material Standard Code: ASTM A706
Material Grade: 60
Rebar Manufacturer: Nucor
Coupler Manufacturer: Bar Splice
Intermediate Assembler or Fabricator:
Rebar Size: #5
Coupler Model: Barsplice Double Barrel Zap Screwlok
Coating Standards: Uncoated
Shape of Rebar: Straight
Rebar Hoop Diameter:
Rebar Hoop Fabricator:
Coupler Component Heat/Lot Number(s): 7048, 80172
Rebar Heat Number(s): PL17108760
Rebar Size 2 :

Test Information

DIME Test ID: 2018-03-02-1-1
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Verified Date: 04/06/2018
Date Tested: 04/05/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test: Service Splice
Additional Comments When Verified:

Submitted Test Results

Number of Samples 1
SampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
23#5/16mm0.312938094770Service SpliceFred
UTM 400KIP
Temperature 72 F