Sample Record for 2020-07-28-26

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

Project ID: 214221 DEA: 081F1424 EFIS: 0815000232 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-15-23.9/33.4
Work Description: REPLACE INDIVIDUAL PCC SLABS, GRIND PCC PAVEMENT AND UPGRADE GUARDRAIL
Location Description: RIVERSIDE COUNTY NEAR LAKE ELSINORE FROM NICHOLS ROAD OVERCROSSING TO 0.2 MILE NORTH OF TEMESCAL CANYON ROAD UNDERCROSSING
Contractor Name: Myers & Sons Construction
Contractor Address: 4600 Northgate Boulevard, Suite 100, Sacramento, CA 95834-1121
Resident Engineer: Denise Sostrom Structure Rep.: Vega, Arnel

Sample Information

DIME Sample ID: 2020-07-28-26
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Sample Organization Contact: (951) 840-8328
Type of Sample: Quality Assurance
Type of Material: Concrete
Sample Taken Date: 07/28/2020
Date that the sample was received by the laboratory/organization performing the testing: 07/28/2020
The quantity of what the sample constitutes: 3 beams
A brief description of the sample: PCC Rapid set beams
From where was the sample collected: Job Site
Laboratory sample identification: 37RA, 37RB, 37RC
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: MSC Plant 1

Material Information

The concrete mix design number: 800-5RSC
The truck number from where the sample was collected:
The batch plant ticket number from where the sample was collected: TT
Concrete batch plant:
The fabricator/manufacturer designation for the sample:
A detailed description of where the material sample was collected: concrete sample from wheel barrow
Where the material sample would have been placed if not sampled:
From Lot No.:
Bag Lot No.:

Test Results

Test Information 3 of 3

DIME Test ID: 2020-07-28-26-3
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Verified Date: 08/01/2020
Date Tested: 07/31/2020
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria St,
Organization City: Fontana
Organization State: CA
Organization Zipcode: 92336
Organization Email: kaushalkumar.talati@dot.ca.gov
Organization Phone: (951) 840-8328
General Comments for this Test:
Additional Comments When Verified:
Fracture initiates in the tension surface Within the Middle Third of the Span Length
Fracture occurred at a capped section No
Modulus of rupture 800 psi

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
No tests have been assigned to this sample.