*Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Sample Record for 2020-05-29-14


Project Information

Project ID: 214314 DEA: 081F6904 EFIS: 0815000016 QA Service Level: 1
DIST-CO-RTE-PM: 08-RIV-79-0.0/15.6
Work Description: COLD PLANE AC PAVEMENT AND PLACE RHMA-G.
Location Description: RIVERSIDE COUNTY NEAR TEMECULA FROM SAN DIEGO COUNTY LINE TO 0.4 MILE EAST OF BUTTERFIELD STAGE ROAD
Contractor Name: All American Asphalt Contractor Address: P.O. Box 2229
Resident Engineer: Osama Abdalla Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2020-05-29-14
TL Number from the TL Form:
Sample Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Sample Organization Contact: (951) 840-8328
Type of Sample: Acceptance
Type of Material: Aggregate
Sample Taken Date: 05/29/2020
Date that the sample was received by the laboratory/organization performing the testing: 06/02/2020
The quantity of what the sample constitutes: 1 bag combined aggregate
A brief description of the sample: AC Drum Aggregate
From where was the sample collected: Manufacturer
Laboratory sample identification:
Structure unique identifier:
Structure name:

Material Information

Source Identification (SMARA or name of Pit): 91-33-0005::ALL AMERICAN ASPHALT
The fabricator's/manufacturer's product name for the sample: Unknown
The fabricator/manufacturer designation for the sample: Unknown
The plant number: Unknown
A detailed description of where the material sample was collected: belt an chute
Where the material sample would have been placed if not sampled: Unknown
Primary Aggregate Nominal Size: 3/4 inch
The concrete mix design number: Unknown
Lot number: Unknown
Sublot number: Unknown

Test Results

Test Information 2 of 2

DIME Test ID: 2020-05-29-14-2
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Verified Date: 06/11/2020
Date Tested: 06/03/2020
Submitted By Organization: CT D08 - Fontana Field Testing Laboratory
Organization Address: 13970 Victoria St
Test General Comments:
Additional Comments When Verified:
Sand Equivalent 75