Print Report | Back to Sample Detail

Sample Record for 2018-10-25-1

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: No Project QA Service Level:
DIST-CO-RTE-PM: ---
Work Description: Special project identifier for material not associated with a project
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2018-10-25-1
TL Number from the TL Form: Unknown
Sample Submitted By Organization: CT - Unassigned/General Field Laboratory
Sample Organization Contact: (510) 385-8178
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 10/25/2018
Date that the sample was received by the laboratory/organization performing the testing: 10/25/2018
The quantity of what the sample constitutes: 13
A brief description of the sample: F1554 Grade 55 HDG Anchor Bolts
From where was the sample collected: Source
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: Blue Circle

Material Information

Rocap Number(s):
Heat Number(s): 1201001787, 177863,
Nut Mfg. Lot Number(s): DDYN 1-1/2 / DDYC 2
Washer Mfg. Lot Number(s): xxxx
Bolt Specification: F1554 Gr. 55
Bolt Length(s): 54"
Nut Specification: A563-DH
Washer Specification: xxx
Finish: Galvanized
Diameter/Size: 2-1/4", 1-1/2", 2"
Bolt Mfg. Lot Number: 120100178721
Rocap Test Requirement(s): xxx
Lubricant Requirements(s):

Test Results

Test Information 1 of 35

DIME Test ID: 2018-10-25-1-1
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Verified Date: 11/01/2018
Date Tested: 10/31/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Additional Comments When Verified:
Number of Samples 1
SampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
112010017870.5010.197616948586026.6Fred
UTM 67KIP
Temperature 72 f

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To
No tests have been assigned to this sample.