Print Report | Back to Sample Detail

Sample Record for 2018-10-16-11

Note: Fields with no data or with a value of "Unknown" will not be displayed on the print out.

Project Information

DEA: No Project QA Service Level:
DIST-CO-RTE-PM: ---
Work Description: Special project identifier for material not associated with a project
Location Description:
Contractor Name: Unknown
Contractor Address: Unknown
Resident Engineer: Unknown Structure Rep.: Unknown

Sample Information

DIME Sample ID: 2018-10-16-11
TL Number from the TL Form: NA
Sample Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Sample Organization Contact: (916) 227-7253
Type of Sample: Quality Assurance
Type of Material: SMTL TM3 - Fastener Assembly
Sample Taken Date: 10/16/2018
Date that the sample was received by the laboratory/organization performing the testing: 10/23/2018
The quantity of what the sample constitutes: 5
A brief description of the sample: A325 Bolts
From where was the sample collected: Distributor
Laboratory sample identification: Unknown
Structure unique identifier:
Structure name:
The fabricator/manufacturer/facility name: KT Bolt JLK Industries Inc

Material Information

Rocap Number(s):
Heat Number(s):
Nut Mfg. Lot Number(s):
Washer Mfg. Lot Number(s):
Bolt Specification: A325 F3125
Bolt Length(s): 3.75
Nut Specification: NA
Washer Specification: NA
Finish: F2329
Diameter/Size: 1.5
Bolt Mfg. Lot Number: 89106-2
Rocap Test Requirement(s):
Lubricant Requirements(s):

Test Results

Test Information 6 of 13

DIME Test ID: 2018-10-16-11-6
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Verified Date: 10/24/2018
Date Tested: 10/24/2018
Submitted By Organization: CT HQ - Sacramento Structural Materials Testing Laboratory
Organization Address: 5900 Folsom Blvd,
Organization City: Sacramento
Organization State: CA
Organization Zipcode: 95819
Organization Email: paul.lukkarila@dot.ca.gov
Organization Phone: (916) 227-7253
General Comments for this Test:
Additional Comments When Verified:
Sample No. 1A
Rocap Number no data
Heat Number(s) no data
Mfg. Lot Number 89106-2
Finish Coating ASTM F2329 - Hot Dip
Product Markings KT A325
Size 1.5 in
Bolt Length 3.75 in
Measurement Average 3.72 mils

Tests Assigned to this Sample

DIME Test IDTest MethodAssigned DateTest DateAssigned ByAssigned LabTest CommentsAssigned To