Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2016-12-21-7

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 210771
DEA: 11413604
EFIS: 1113000036
DIST-CO-RTE-PM11-IMP-8,154-R45.5/R55.0
Award Date11/18/2015
Closeout Date08/20/2018
Work DescriptionCONSTRUCT CRCP, HMA-A, GUARDRAIL, RUMBLE STRIPS AND APPROACH SLABS
Location DescriptionIN IMPERIAL COUNTY NEAR EL CENTRO FROM 0.6 MILE WEST OF ANDERHOLT ROAD OVERCROSSING TO 0.5 MILE EAST OF EAST HIGHLINE CANAL BRIDGE
QA Service Level1 (Verified on 12/09/2015)

Sample Information

Sample Taken Date12/21/2016 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/28/2016
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes4 From where was the sample collectedFabricator
First name of sampler or witnessed byTory Last name of sampler or witnessed byMclaurin
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameTNT Rebar CMC Rebar Transportation Laboratory (TL) NumberC953856
Inspector Lot Number from the Transportation Laboratory (TL) FormL6737116 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)4049973
Hoop Manufacturer Lot Number(s)4 Material Standard CodeASTM A706
Material Grade60 Rebar Size4
Diameter of Hoop2'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Rebar
Welding CompanyTNT Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2016-12-21-7-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory12/28/2016Fred
Yes
01/04/2017
2016-12-21-7-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory12/28/2016Fred
Yes
01/04/2017necking okay
2016-12-21-7-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory12/28/2016Fred
Yes
01/04/2017necking okay
2016-12-21-7-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory12/28/2016Fred
Yes
01/04/2017Bar Broke in Heat Affected Area necking okay

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-12-21-7-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-12-21-7-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-12-21-7-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-12-21-7-4 CTM 670-December 2013 (Verified)