Sample Record

Owner Lab

  • CT HQ - QASI Sacramento Field Office

DIME Sample ID 2024-08-13-11

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 77777
DEA: CHEM-STOCK
EFIS: CHEM-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for Chem Lab stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date08/13/2024 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/15/2024
Sample typeAuthorization A brief description of the sampleFor audit certification
The quantity of what the sample constitutesLot From where was the sample collectedFabricator
First name of sampler or witnessed byPaul Last name of sampler or witnessed byFarinha
Title of samplerASI Telephone number of sampler9167987102
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCMC Brighton CO Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM7 - Epoxy Coated Rebar Rebar Heat Number(s)6051570
Rebar Epoxy Batch Number(s)G240359 Rebar Coating SpecificationASTM A775
Rebar Size (#)5 Rebar Coating ColorGreen
Rebar ManufacturerCMC Steel Oklahoma Rebar CoaterCMC Brighton CO
Rebar Powder ManufacturerSherwin Williams Release Number
Quality Assurance Code

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2024-08-13-11-1ASTM A775-19: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Epoxy Coating)Andrew Auvinen, CT HQ - Sacramento Structural Materials Testing Laboratory08/16/2024Andrew Auvinen
Yes
08/21/2024
2024-08-13-11-2ASTM A775-19: Standard Specification for Epoxy-Coated Steel Reinforcing Bars (Holiday)Andrew Auvinen, CT HQ - Sacramento Structural Materials Testing Laboratory08/16/2024Andrew Auvinen
Yes
08/21/2024

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-08-13-11-1 ASTM A775-19 (Verified)
DIME Test ID: 2024-08-13-11-2 ASTM A775-19 (Verified)