Sample Record

Owner Lab

  • CT D06 - Bakersfield Field Laboratory

DIME Sample ID 2024-08-01-57

Project Information

Project IdentifiersProject ID: 1000010
DEA: 061F8904
EFIS: 0623000107
DIST-CO-RTE-PM06-TUL-63-4.0/5.5
Award Date03/20/2024
Closeout DateNot set
Work DescriptionCOLD PLANE AC PAVEMENT AND PLACE HMA.
Location DescriptionTULARE COUNTY IN AND NEAR VISALIA FROM AVENUE 264 TO VISALIA PARKWAY
QA Service Level1 (Verified on 01/08/2024)

Sample Information

Sample Taken Date08/01/2024 Sample Unique Key57
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing08/01/2024
Sample typeAcceptance A brief description of the sampleHMA
The quantity of what the sample constitutesL1SL2 From where was the sample collectedSource
First name of sampler or witnessed byT Last name of sampler or witnessed byHall
Title of samplerMaterials Tester Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameJaxon Baker/Deer Creek Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-54-0021
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedcoldfeed
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number1
Sublot number2 Aggregate Mix Number

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2024-08-01-57-1AASHTO T11-5: Standard Method of Test for Materials Finer Than 75-μm (No. 200) Sieve in Mineral Aggregates by WashingCorey Hicks, CT D06 - Bakersfield Field Laboratory08/01/2024Kulwinder Rai
Yes
08/06/2024
2024-08-01-57-2AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)Corey Hicks, CT D06 - Bakersfield Field Laboratory08/01/2024Kulwinder Rai
Yes
08/06/2024
2024-08-01-57-3AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)Corey Hicks, CT D06 - Bakersfield Field Laboratory08/01/2024Kulwinder Rai
Yes
08/06/2024

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-08-01-57-1 AASHTO T11-5 (Verified)
DIME Test ID: 2024-08-01-57-2 AASHTO T176-08 (Verified)
File NameExtensionDate UploadedTest IDActions
06-1F8904_37014_240801_L1SL02_T027_HMApdf08/06/20242024-08-01-57-2   Info

DIME Test ID: 2024-08-01-57-3 AASHTO T27-14 (Verified)
File NameExtensionDate UploadedTest IDActions
06-1F8904_37014_240801_L1SL02_T027_HMApdf08/06/20242024-08-01-57-3   Info