Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2016-12-07-5

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 211004
DEA: 05330784
EFIS: 0512000076
DIST-CO-RTE-PM05-SLO-46-46.0/50.2
Award Date02/10/2016
Closeout Date10/15/2019
Work DescriptionCONVERT 2-LANE TO 4 LANE EXPRESSWAY.
Location DescriptionNEAR SHANDON FROM 0.2 MILE EAST OF MCMILLIAN CANYON ROAD TO 0.4 MILE WEST OF LUCY BROWN ROAD
QA Service Level1 (Verified on 01/08/2016)

Sample Information

Sample Taken Date12/07/2016 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/09/2016
Sample typeQuality Assurance A brief description of the sampleBar Lock Couplers
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byJose Last name of sampler or witnessed byBaal
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameGerdau Dayton Superior Transportation Laboratory (TL) NumberC749158
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerGerdau
Coupler ManufacturerDayton Superior Intermediate Assembler or FabricatorUnknown
Rebar Size#4 Coupler ModelBar Lock Stanard Coupler
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)A152317 Rebar Heat Number(s)5314108602, 6502505402
Rebar Size 2 Not set Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2016-12-07-5-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory12/12/2016Fred
Yes
12/19/2016Service Splice
2016-12-07-5-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory12/12/2016Fred
Yes
12/19/2016Service Splice
2016-12-07-5-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory12/12/2016Fred
Yes
12/19/2016Service Splice

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-12-07-5-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-12-07-5-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-12-07-5-3 CTM 670-December 2013 (Verified)