Sample Record
Owner Labs
- CT SC - 3667 - Chico
- CT D03 - Chico Field Laboratory
DIME Sample ID 2024-07-26-11
Project Information
Project Identifiers | Project ID: 994309 DEA: 033H5404 EFIS: 0318000012 |
---|---|
DIST-CO-RTE-PM | 03-BUT-70-46.0/47.0 |
Award Date | 02/10/2023 |
Closeout Date | Not set |
Work Description | RAISE ALIGNMENT, PLACE HMA, STRUCTURAL CONCRETE & BRIDGE RAIL. |
Location Description | BUTTE COUNTY NEAR PARADISE FROM 0.8 MILE WEST OF SHADY REST AREA TO 0.2 MILE EAST OF SHADY REST AREA |
QA Service Level | 1 (Verified on 10/04/2022) |
Sample Information
Sample Taken Date | 07/26/2024 | Sample Unique Key | 11 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 07/29/2024 |
Sample type | Quality Assurance | A brief description of the sample | PCC |
The quantity of what the sample constitutes | 3 4x8 concrete cylinders | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Adam | Last name of sampler or witnessed by | Scardaci |
Title of sampler | Structure Representative | Telephone number of sampler | 530-604-0153 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Matthews Ready Mix | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name | Soldier Pile Wall #1 piles 195-215 |
Material Information
Material Type | Concrete | The concrete mix design number | G7215PA |
---|---|---|---|
The truck number from where the sample was collected | 735 | The batch plant ticket number from where the sample was collected | 16028197 |
Concrete batch plant | Mathews Readymix Oroville | The fabricator/manufacturer designation for the sample | |
A detailed description of where the material sample was collected | collected from chute | Where the material sample would have been placed if not sampled | soldier pile wall |
From Lot No. | Bag Lot No. |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2024-07-26-11-1 ASTM C39-18 (Verified)