Sample Record
Owner Lab
- CT HQ - QASI Los Angeles Field Office
DIME Sample ID 2024-07-23-34
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 995202 DEA: 033H6104 EFIS: 0318000019 |
---|---|
DIST-CO-RTE-PM | 03-PLA-80-42.7/49.3 |
Award Date | 02/15/2024 |
Closeout Date | Not set |
Work Description | RDWY EXC, HMA, JPCP, ALT PIPELINER, STEEL SOLDIER PILE, MOD LTG SYSTEM |
Location Description | PLACER COUNTY ABOUT 9.4 MILES NORTH OF COLFAX FROM 0.5 MILE WEST OF MONTE VISTA OVERCROSSING TO 0.3 MILE EAST OF DRUM FOREBAY OVERCROSSING |
QA Service Level | 1 (Verified on 11/13/2023) |
Sample Information
Sample Taken Date | 07/23/2024 | Sample Unique Key | 34 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/26/2024 |
Sample type | Quality Assurance | A brief description of the sample | #10 x 5' |
The quantity of what the sample constitutes | 3 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Lorenzo | Last name of sampler or witnessed by | Garcia |
Title of sampler | Quality Assurance Inspector | Telephone number of sampler | 7029172503 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Dywidag Systems International | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L115-106-24 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM5 - Threaded Bar | Production or Authorization Testing | Production Testing |
---|---|---|---|
Threaded Bar Specification | ASTM A615 | Threaded Bar Grade | 75 |
Threaded Bar Type | Deformed | Rebar Size | #10 |
Nut Specification for Threaded Bar | ASTM A897 | System Manufacturer | Farrar Corporation |
Epoxy Coating Color | NA | Threaded Bar Application | Soil Nail |
Coating Standards | Uncoated | Bar Heat Number(s) | 58059057/02 |
Nut Heat Number(s) | B274 | Bar Lot Number | 58059057/02 |
Nut Lot Number | B274 | Coupler Heat Number(s) | N/A |
Coupler Grade | N/A |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2024-07-23-34-1 ASTM A615-20 (Verified)
DIME Test ID: 2024-07-23-34-2 ASTM A615-20 (Verified)