Sample Record

Owner Lab

  • CT HQ - QASI Bay Area Field Office

DIME Sample ID 2024-06-20-20

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date06/20/2024 Sample Unique Key20
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/28/2024
Sample typeQuality Assurance A brief description of the sampleROCAP Assembly
The quantity of what the sample constitutes500 From where was the sample collectedFabricator
First name of sampler or witnessed byDavid Last name of sampler or witnessed byLund
Title of samplerCT METS QA INSPECTOR Telephone number of sampler1-385-452-2398
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameUniversal Industrial Sales, Inc Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB390-092-24 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)TT0179161
Heat Number(s)10855170, 234317, 233270 Nut Mfg. Lot Number(s)38872-S-234317
Washer Mfg. Lot Number(s)233270-29467 Bolt SpecificationA325
Bolt Length(s)5" Nut SpecificationA563-DH
Washer SpecificationF436 FinishMG
Diameter/Size1" Bolt Mfg. Lot NumberBM1261
Rocap Test Requirement(s) Lubricant Requirements(s)Wax and Dye

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2024-06-20-20-1ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory07/09/2024aauvinen
Yes
07/12/2024Wedge Tensile
2024-06-20-20-2ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)aauvinen, CT HQ - Sacramento Structural Materials Testing Laboratory07/09/2024aauvinen
Yes
07/12/2024Wedge Tensile
2024-06-20-20-3ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)<None>, CT HQ - Sacramento Structural Materials Testing Laboratory07/09/2024<None>
Yes
07/12/2024Proof Load
2024-06-20-20-4ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)<None>, CT HQ - Sacramento Structural Materials Testing Laboratory07/09/2024<None>
Yes
07/12/2024Proof Load
2024-06-20-20-5ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Andrew Auvinen, CT HQ - Sacramento Structural Materials Testing Laboratory07/11/2024Andrew Auvinen
Yes
07/12/2024
2024-06-20-20-6ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Andrew Auvinen, CT HQ - Sacramento Structural Materials Testing Laboratory07/11/2024Andrew Auvinen
Yes
07/12/2024
2024-06-20-20-7ASME B1.2-83r17: (Ring Gage) Gages and Gaging for Unified Inch Screw Threads - Errata May 1992 (Ring Gage)Andrew Auvinen, CT HQ - Sacramento Structural Materials Testing Laboratory07/11/2024Andrew Auvinen
Yes
07/12/2024
2024-06-20-20-8ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)Andrew Auvinen, CT HQ - Sacramento Structural Materials Testing Laboratory07/11/2024Andrew Auvinen
Yes
07/12/2024
2024-06-20-20-9ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)Andrew Auvinen, CT HQ - Sacramento Structural Materials Testing Laboratory07/11/2024Andrew Auvinen
Yes
07/12/2024
2024-06-20-20-10ASTM B499-09r21: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)Andrew Auvinen, CT HQ - Sacramento Structural Materials Testing Laboratory07/11/2024Andrew Auvinen
Yes
07/12/2024

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-06-20-20-1 ASTM F606-21 (Verified)
DIME Test ID: 2024-06-20-20-2 ASTM F606-21 (Verified)
DIME Test ID: 2024-06-20-20-3 ASTM F606-21 (Verified)
DIME Test ID: 2024-06-20-20-4 ASTM F606-21 (Verified)
DIME Test ID: 2024-06-20-20-5 ASME B1.2-83r17 (Verified)
DIME Test ID: 2024-06-20-20-6 ASME B1.2-83r17 (Verified)
DIME Test ID: 2024-06-20-20-7 ASME B1.2-83r17 (Verified)
DIME Test ID: 2024-06-20-20-8 ASTM B499-09r21 (Verified)
DIME Test ID: 2024-06-20-20-9 ASTM B499-09r21 (Verified)
DIME Test ID: 2024-06-20-20-10 ASTM B499-09r21 (Verified)
DIME Test ID: 2024-06-20-20-11 ASTM B499-09r21 (Verified)
DIME Test ID: 2024-06-20-20-12 ASTM B499-09r21 (Verified)
DIME Test ID: 2024-06-20-20-13 ASTM B499-09r21 (Verified)
DIME Test ID: 2024-06-20-20-14 ASTM B499-09r21 (Verified)
DIME Test ID: 2024-06-20-20-15 ASTM B499-09r21 (Verified)
DIME Test ID: 2024-06-20-20-16 ASTM B499-09r21 (Verified)
DIME Test ID: 2024-06-20-20-17 ASTM E18-20 (Verified)
DIME Test ID: 2024-06-20-20-18 ASTM E18-20 (Verified)
DIME Test ID: 2024-06-20-20-19 ASTM E18-20 (Verified)