Sample Record
Owner Lab
- Con-Fab California Corporation - Lathrop
DIME Sample ID 2024-06-10-41
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 1000310 DEA: 041X5804 EFIS: 0424000402 |
---|---|
DIST-CO-RTE-PM | 04-SON-116-19.9 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Remove 12" AC overlay on the Jones Creek Bridge and Install precast pre-stressed slab girder. |
Location Description | Jones Creek Bridge (Bridge # 20-0094) in Sonoma 116 post mile 19.9 |
QA Service Level | 1 (Verified on 05/14/2024) |
Sample Information
Sample Taken Date | 06/10/2024 | Sample Unique Key | 41 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/11/2024 |
Sample type | Quality Control | A brief description of the sample | 1 cubic ft. of Concrete taken from middle of batching |
The quantity of what the sample constitutes | 1 cubic ft. of Concrete for Testing | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Mark Patrick | Last name of sampler or witnessed by | Baddu |
Title of sampler | Telephone number of sampler | 2092492724 | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | ConFab California, LLC, Lathrop | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | VER-85LV |
---|---|---|---|
The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 10997 | |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | Bed 1A at 2nd truck | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2024-06-10-41-1 ASTM C143-20 (Verified)
DIME Test ID: 2024-06-10-41-2 ASTM C39-21 (Verified)
DIME Test ID: 2024-06-10-41-3 ASTM C1064-17 (Verified)
DIME Test ID: 2024-06-10-41-4 CTM TEMP1-16 (Verified)
DIME Test ID: 2024-06-10-41-5 ASTM C138-17a (Verified)