Sample Record
Owner Lab
- CT D01 - Crescent City Field Laboratory
DIME Sample ID 2024-05-14-92
Project Information
Project Identifiers | Project ID: 214579 DEA: 010B0904 EFIS: 0100020444 |
---|---|
DIST-CO-RTE-PM | 01-DN-101-8.2/8.7 |
Award Date | 04/21/2020 |
Closeout Date | Not set |
Work Description | Panther Creek & Hunter Creek Bridges |
Location Description | DEL NORTE COUNTY NEAR KLAMATH AT PANTHER CREEK BRIDGE AND AT HUNTER CREEK BRIDGE |
QA Service Level | 1 (Verified on 03/02/2020) |
Sample Information
Sample Taken Date | 05/14/2024 | Sample Unique Key | 92 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/14/2024 |
Sample type | Quality Assurance | A brief description of the sample | 1/2" aggregate |
The quantity of what the sample constitutes | 2 Bags | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Jason | Last name of sampler or witnessed by | Huett |
Title of sampler | TET | Telephone number of sampler | 707-815-5590 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Mercer Fraser Boyd RD | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-12-0010 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | plant from cold feed before dryer drum | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number |
Submitted Tests
DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Submitted By | Verified? | Release Date | Test Comments | Actions |
---|---|---|---|---|---|---|---|---|
2024-05-14-92-1 | AASHTO T11-5: Standard Method of Test for Materials Finer Than 75-μm (No. 200) Sieve in Mineral Aggregates by Washing | jason huett, CT D01 - Crescent City Field Laboratory | 05/23/2024 | jason huett | No | Info | ||
2024-05-14-92-2 | AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent) | jason huett, CT D01 - Crescent City Field Laboratory | 05/23/2024 | jason huett | No | Info | ||
2024-05-14-92-3 | AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis) | jason huett, CT D01 - Crescent City Field Laboratory | 05/23/2024 | jason huett | No | Info |
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2024-05-14-92-1 AASHTO T11-5
DIME Test ID: 2024-05-14-92-2 AASHTO T176-08
DIME Test ID: 2024-05-14-92-3 AASHTO T27-14