Sample Record

Owner Labs

  • Kie-Con, Incorporated - Antioch
  • CT HQ - QASI Sacramento Field Office

DIME Sample ID 2024-05-13-10

Project Information

Project Identifiers
DEA: No Project
DIST-CO-RTE-PM---
Award DateNot set
Closeout Date11/01/2022
Work DescriptionSpecial project identifier for material not associated with a project
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date05/13/2024 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing05/13/2024
Sample typeQuality Control A brief description of the samplePrecast WFG
The quantity of what the sample constitutes20 cy From where was the sample collectedFabricator
First name of sampler or witnessed byPeter Last name of sampler or witnessed byHarvey
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameKie-Con, Antioch Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design number1234test
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedbatchticket
Concrete batch plantKie Con The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedLoad 4 of 10 Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2024-05-13-10-1ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement ConcretePeter Harvey, CT HQ - QASI Sacramento Field Office05/13/2024Peter Harvey
No
Info
2024-05-13-10-2ASTM C173-10b: Standard Test Method for Air Content of Freshly Mixed Concrete by the Volumetric MethodPeter Harvey, CT HQ - QASI Sacramento Field Office05/13/2024Peter Harvey
No
Info
2024-05-13-10-4ASTM C1064-08: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement ConcretePeter Harvey, CT HQ - QASI Sacramento Field Office05/13/2024Peter Harvey
No
Info
2024-05-13-10-5ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensPeter Harvey, CT HQ - QASI Sacramento Field Office05/13/2024Peter Harvey
No
Info

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2024-05-13-10-1 ASTM C143-20
DIME Test ID: 2024-05-13-10-2 ASTM C173-10b
DIME Test ID: 2024-05-13-10-4 ASTM C1064-08
DIME Test ID: 2024-05-13-10-5 ASTM C39-21