Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2016-08-18-9

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 211606
DEA: 051F9104
EFIS: 0514000074
MINOR: 05A1875
DIST-CO-RTE-PM05-SLO-101-55.7
Award DateNot set
Closeout DateNot set
Work DescriptionPlace Changeable Message Sign and Closed Circuit Television in Paso Robles at South Paso Robles Overhead
Location DescriptionNot set
QA Service Level1 (Verified on 07/27/2016)

Sample Information

Sample Taken Date08/18/2016 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/22/2016
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes4 From where was the sample collectedFabricator
First name of sampler or witnessed bykevin Last name of sampler or witnessed byChurchill
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameTNT Rebar Transportation Laboratory (TL) Number648119
Inspector Lot Number from the Transportation Laboratory (TL) FormL0209316 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)PL14104777
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size4
Diameter of Hoop2'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerNucor
Welding CompanyTNT Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2016-08-18-9-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory08/24/2016Brian
Yes
08/24/2016Bar Broke in Heat Affected Area
2016-08-18-9-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory08/24/2016Brian
Yes
08/24/2016Bar Broke in Heat Affected Area
2016-08-18-9-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory08/24/2016Brian
Yes
08/24/2016Bar Broke; OK Necking
2016-08-18-9-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory08/24/2016Brian
Yes
08/24/2016Bar Broke in Heat Heat Affected Area

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-08-18-9-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-08-18-9-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-08-18-9-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-08-18-9-4 CTM 670-December 2013 (Verified)