Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2016-08-09-5

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 210886
DEA: 050F7004
EFIS: 0500000049
DIST-CO-RTE-PM05-MON-68-R17.4/R18.0
Award Date01/22/2016
Closeout Date12/30/2019
Work DescriptionWIDENING BRIDGE
Location DescriptionIN MONTEREY COUNTY ON ROUTE 68 NEARSALINAS FROM 0.2 MILE EAST OFRESERVATION ROAD UNDERCROSSING TO SPRECKELS BOULEVARD UNDERCROSSING
QA Service Level1 (Verified on 02/01/2016)

Sample Information

Sample Taken Date08/09/2016 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/11/2016
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes4 From where was the sample collectedFabricator
First name of sampler or witnessed byEd Last name of sampler or witnessed byFleming
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationH12 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameHarris Rebar Transportation Laboratory (TL) NumberC715274
Inspector Lot Number from the Transportation Laboratory (TL) FormB1034116 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)586353
Hoop Manufacturer Lot Number(s)H12 Material Standard CodeASTM A706
Material Grade60 Rebar Size5
Diameter of Hoop2'-6.5" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerAVRAZ
Welding CompanyHarris Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2016-08-09-5-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory08/11/2016Brian
Yes
08/11/2016Bar Broke; OK Necking
2016-08-09-5-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory08/11/2016Brian
Yes
08/11/2016Bar Broke; OK Necking
2016-08-09-5-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory08/11/2016Brian
Yes
08/11/2016Bar Broke; OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-08-09-5-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-08-09-5-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-08-09-5-3 CTM 670-December 2013 (Verified)