Owner Lab
- CT HQ - Sacramento Structural Materials Testing Laboratory
DIME Sample ID 2016-07-25-11
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 210959 DEA: 08465524 EFIS: 0815000118 MINOR: 08A2540 |
DIST-CO-RTE-PM | 08-RIV-74-16.1/71.8 |
Award Date | 08/06/2015 |
Closeout Date | 08/10/2018 |
Work Description | CONSTRUCTION ON STATEĆ ? HIGHWAY IN VARIOUS CITIES, ROUTES AND POST MILES IN RIVERSIDE COUNTY. |
Location Description | Various locations in Riverside County |
QA Service Level | 1 (Verified on 10/15/2015) |
Sample Information
Sample Taken Date | 07/25/2016 |
Sample Unique Key | 11 |
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes |
Date that the sample was received by the laboratory/organization performing the testing | 07/28/2016 |
Sample type | Quality Assurance |
A brief description of the sample | Flash Welded Rebar Hoops |
The quantity of what the sample constitutes | 4 |
From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Russel |
Last name of sampler or witnessed by | Lynch |
Title of sampler | Unknown |
Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown |
Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | TNT Rebar Nucor |
Transportation Laboratory (TL) Number | C952650 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L9607416 |
Structure unique identifier | Not set |
Structure name | Not set |
---|
Material Information
Material Type | SMTL TM5 - Welded Hoops |
Production or Authorization Testing | Production Testing |
Service or Ultimate | Ultimate |
Rebar Heat Number(s) | PL1410777 |
Hoop Manufacturer Lot Number(s) | 1, 2 |
Material Standard Code | ASTM A706 |
Material Grade | 60 |
Rebar Size | 4 |
Diameter of Hoop | 2'-2" |
Epoxy Coated | No |
Epoxy Coating Color | NA |
Rebar Manufacturer | Nucor |
Welding Company | TNT Rebar |
Coating Standards | Uncoated |
Weld Type | Flash Welded |
---|
Submitted Tests
DIME Test ID | Test Method | Tester Name | Testing Lab | Date Tested | Submitted By | Verified? | Release Date | Test Comments | Actions |
2016-07-25-11-1 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile) | Fred | CT HQ - Sacramento Structural Materials Testing Laboratory | 07/29/2016 | Fred | Yes | 08/01/2016 | Bar Broke in Heat Affected Area; NO Necking | |
2016-07-25-11-2 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile) | Fred | CT HQ - Sacramento Structural Materials Testing Laboratory | 07/29/2016 | Fred | Yes | 08/01/2016 | Bar Broke in Heat Affected Area; NO Necking | |
2016-07-25-11-3 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile) | Fred | CT HQ - Sacramento Structural Materials Testing Laboratory | 07/29/2016 | Fred | Yes | 08/01/2016 | Bar Broke in Heat Affected Area; NO Necking | |
2016-07-25-11-4 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile) | Fred | CT HQ - Sacramento Structural Materials Testing Laboratory | 07/29/2016 | Fred | Yes | 08/01/2016 | Bar Broke in Heat Affected Area; NO Necking | |
2016-07-25-11-5 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile) | Fred | CT HQ - Sacramento Structural Materials Testing Laboratory | 07/29/2016 | Fred | Yes | 08/01/2016 | Bar Broke in Heat Affected Area; NO Necking | |
2016-07-25-11-6 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile) | Fred | CT HQ - Sacramento Structural Materials Testing Laboratory | 07/29/2016 | Fred | Yes | 08/01/2016 | Bar Broke in Heat Affected Area; OK Necking | |
2016-07-25-11-7 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile) | Fred | CT HQ - Sacramento Structural Materials Testing Laboratory | 07/29/2016 | Fred | Yes | 08/01/2016 | Bar Broke; OK Necking | |
2016-07-25-11-8 | CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile) | Fred | CT HQ - Sacramento Structural Materials Testing Laboratory | 07/29/2016 | Fred | Yes | 08/01/2016 | Bar Broke in Heat Affected Area; NO Necking | |
1722717228172291723017231172321723317234