Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2016-07-25-10

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 210967
DEA: 08464904
EFIS: 0815000068
MINOR: 08A2539
DIST-CO-RTE-PM08-SBD-18-35.7/35.7
Award Date08/25/2015
Closeout Date05/10/2017
Work DescriptionInstall 7 Solar Powered Traffic Monitoring Stations
Location DescriptionNot set
QA Service Level1 (Verified on 10/07/2015)

Sample Information

Sample Taken Date07/25/2016 Sample Unique Key10
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/28/2016
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes4 From where was the sample collectedFabricator
First name of sampler or witnessed byRussel Last name of sampler or witnessed byLynch
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameTNT Rebar Nucor Transportation Laboratory (TL) NumberC970402
Inspector Lot Number from the Transportation Laboratory (TL) FormL9607616 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)PL1410777
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size4
Diameter of Hoop2'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerNucor
Welding CompanyTNT Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2016-07-25-10-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory07/29/2016Fred
Yes
08/01/2016Bar Broke; OK Necking
2016-07-25-10-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory07/29/2016Fred
Yes
08/01/2016Bar Broke in Heat Affected Area; NO Necking
2016-07-25-10-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory07/29/2016Fred
Yes
08/01/2016Bar Broke in Heat Affected Area; NO Necking
2016-07-25-10-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory07/29/2016Fred
Yes
08/01/2016Bar Broke in Heat Affected Area; NO Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-07-25-10-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-07-25-10-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-07-25-10-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-07-25-10-4 CTM 670-December 2013 (Verified)