Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2016-06-27-8

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 8196
DEA: 59912684
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work Description
Location Description
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date06/27/2016 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/04/2016
Sample typeAuthorization A brief description of the sampleHY Ten Coupler
The quantity of what the sample constitutes12 From where was the sample collectedManufacturer
First name of sampler or witnessed byRichard Last name of sampler or witnessed byWebster
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameHY Ten Reinforcement Transportation Laboratory (TL) NumberNA
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerHY Ten
Coupler ManufacturerHY Ten Intermediate Assembler or FabricatorUnknown
Rebar Size#4, 5, 6, 8, 14 Coupler ModelHTS HTP HTL
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)4, 5, 6, 8, 14, HTS, HTP, HTL Rebar Heat Number(s)4049941, 4051049, 4048405, 4050513, 3055577
Rebar Size 2 NA Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2016-06-27-8-14CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory01/13/2017Fred
Yes
01/27/2017necking okay
2016-06-27-8-15CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory01/13/2017Fred
Yes
01/27/2017necking okay
2016-06-27-8-16CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory01/13/2017Fred
Yes
01/27/2017necking okay
2016-06-27-8-17CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory01/13/2017Fred
Yes
01/27/2017necking okay
2016-06-27-8-18CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory01/13/2017Fred
Yes
01/27/2017necking okay
2016-06-27-8-19CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory01/13/2017Fred
Yes
01/27/2017necking okay
2016-06-27-8-20CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory01/13/2017Fred
Yes
01/27/2017necking okay
2016-06-27-8-21CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory01/13/2017Fred
Yes
01/27/2017necking okay
2016-06-27-8-22CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory01/13/2017Fred
Yes
01/27/2017necking okay
2016-06-27-8-23CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Fred, CT HQ - Sacramento Structural Materials Testing Laboratory01/13/2017Fred
Yes
01/27/2017necking okay

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-06-27-8-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-06-27-8-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-06-27-8-6 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-06-27-8-7 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-06-27-8-8 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-06-27-8-9 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-06-27-8-10 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-06-27-8-11 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-06-27-8-12 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-06-27-8-13 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-06-27-8-14 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-06-27-8-15 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-06-27-8-16 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-06-27-8-17 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-06-27-8-18 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-06-27-8-19 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-06-27-8-20 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-06-27-8-21 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-06-27-8-22 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-06-27-8-23 CTM 670-December 2013 (Verified)