Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2016-07-11-8

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 210892
DEA: 100W3604
EFIS: 1000020631
DIST-CO-RTE-PM10-AMA-49-3.6
Award Date12/14/2015
Closeout Date04/12/2018
Work DescriptionINSTALL TRAFFIC SIGNALS AND INTERSECTION IMPROVEMENT.
Location DescriptionIN AMADOR COUNTY IN JACKSON ON STATE ROUTE 49 AT FRENCH BAR ROAD
QA Service Level1 (Verified on 02/17/2016)

Sample Information

Sample Taken Date07/11/2016 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/14/2016
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes4 From where was the sample collectedFabricator
First name of sampler or witnessed byTory Last name of sampler or witnessed byMclaurin
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameRKR Steel Welding Transportation Laboratory (TL) NumberC705707
Inspector Lot Number from the Transportation Laboratory (TL) FormL6713216 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)131715
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size5
Diameter of Hoop3'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCascade
Welding CompanyRKR Steel Welding Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2016-07-11-8-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory07/18/2016Brian
Yes
07/19/2016Bar Broke; OK Necking
2016-07-11-8-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory07/18/2016Brian
Yes
07/19/2016Bar Broke; OK Necking
2016-07-11-8-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory07/18/2016Brian
Yes
07/19/2016Bar Broke; OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-07-11-8-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-07-11-8-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-07-11-8-3 CTM 670-December 2013 (Verified)