Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2016-06-20-2

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 7285
DEA: 040120T4
EFIS: 0400000027
DIST-CO-RTE-PM04-SF-80-12.6/13.9
Award Date11/27/2012
Closeout DateNot set
Work DescriptionCONSTRUCT BRIDGE, ROADWAYS, ELECTRICAL, BUILDINGS AND REMOVE BRIDGES
Location DescriptionTHE CITY AND COUNTY OF SAN FRANCISCO FROM THE YERBA BUENA TUNNEL TO 1.3 KM EAST OF THE YERBA BUENA TUNNEL
QA Service Level1 (Verified on 10/29/2012)

Sample Information

Sample Taken Date06/20/2016 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/21/2016
Sample typeQuality Assurance A brief description of the sampleEnd Anchors
The quantity of what the sample constitutes16 From where was the sample collectedFabricator
First name of sampler or witnessed byGreg Last name of sampler or witnessed byJohnston
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identification1 3 7 12 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameHRC CMC Rebar Transportation Laboratory (TL) NumberC731308
Inspector Lot Number from the Transportation Laboratory (TL) FormL5301316 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingProduction Testing
Rebar Heat Number(s)4056146 Head Manufacturer Lot Number(s)1 3 7 12
Rebar Size#7 Headed Bar Model Name120
Size of HeadReduced Size - 4x Head Connection TypeFriction Weld
Head ShapeSquare Rebar ManufacturerCMC Rebar
Head ManufacturerHRC Head FabricatorHRC
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2016-06-20-2-11ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/22/2016Brian
Yes
06/22/2016Bar Broke; OK Necking
2016-06-20-2-12ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/22/2016Brian
Yes
06/22/2016Bar Broke; OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-06-20-2-1 ASTM A970-15e1 (Verified)
DIME Test ID: 2016-06-20-2-2 ASTM A970-15e1 (Verified)
DIME Test ID: 2016-06-20-2-3 ASTM A970-15e1 (Verified)
DIME Test ID: 2016-06-20-2-4 ASTM A970-15e1 (Verified)
DIME Test ID: 2016-06-20-2-5 ASTM A970-15e1 (Verified)
DIME Test ID: 2016-06-20-2-6 ASTM A970-15e1 (Verified)
DIME Test ID: 2016-06-20-2-7 ASTM A970-15e1 (Verified)
DIME Test ID: 2016-06-20-2-8 ASTM A970-15e1 (Verified)
DIME Test ID: 2016-06-20-2-9 ASTM A970-15e1 (Verified)
DIME Test ID: 2016-06-20-2-10 ASTM A970-15e1 (Verified)
DIME Test ID: 2016-06-20-2-11 ASTM A970-15e1 (Verified)
DIME Test ID: 2016-06-20-2-12 ASTM A970-15e1 (Verified)