Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2016-06-10-3

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 210648
DEA: 034F0404
EFIS: 0314000016
DIST-CO-RTE-PM03-PLA,YUB-65-R23.8/R24.3,0.0/0.6,1.7/R4.8
Award Date09/10/2015
Closeout Date11/30/2017
Work DescriptionHMA OVERLAY
Location DescriptionPLACER AND YUBA COUNTIES, IN AND NEAR WHEATLAND, FROM BEAR RIVER BRIDGE TO 0.10 SOUTH OF MAIN STREET AND FROM GRASSHOPPER SLOUGH BRIDGE TO 0.8 MILES NORTH OF SOUTH BEALE ROAD
QA Service Level1 (Verified on 09/08/2015)

Sample Information

Sample Taken Date06/10/2016 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/14/2016
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes4 From where was the sample collectedFabricator
First name of sampler or witnessed byTory Last name of sampler or witnessed byMc Laurin
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameRKR Welding Transportation Laboratory (TL) NumberC4677226
Inspector Lot Number from the Transportation Laboratory (TL) FormL6709116 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateService Rebar Heat Number(s)131815
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size5
Diameter of Hoop2'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerRKR Steel
Welding CompanyRKR Steel Welding Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2016-06-10-3-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/15/2016Brian
Yes
06/15/2016Service Splice
2016-06-10-3-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/15/2016Brian
Yes
06/15/2016Service Splice
2016-06-10-3-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/15/2016Brian
Yes
06/15/2016Service Splice

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-06-10-3-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-06-10-3-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-06-10-3-3 CTM 670-December 2013 (Verified)