Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2016-06-07-5

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 210871
DEA: 044G4604
EFIS: 0412000480
DIST-CO-RTE-PM04-MRN-101-1.5/14.0
Award Date01/28/2016
Closeout Date10/17/2019
Work DescriptionREMOVE EXISTING AND CONSTRUCT NEW BRIDGE RAILINGS.
Location DescriptionIN MARIN COUNTY, AT VARIOUS LOCATION, FROM SPENCER AVE OVERCROSSING TO NORTH BRANCHGALLINAS CREEK BRIDGE
QA Service Level1 (Verified on 01/12/2016)

Sample Information

Sample Taken Date06/07/2016 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/08/2016
Sample typeQuality Assurance A brief description of the sampleHeaded Bars
The quantity of what the sample constitutes8 From where was the sample collectedJob Site
First name of sampler or witnessed byKevin Last name of sampler or witnessed byChurchill
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameHRC Transportation Laboratory (TL) NumberC952970
Inspector Lot Number from the Transportation Laboratory (TL) FormL0204616 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Headed Bars Production or Authorization TestingAuthorization Testing
Rebar Heat Number(s)4054938 Head Manufacturer Lot Number(s)1 3
Rebar Size#8 Headed Bar Model NameHRC 120
Size of HeadReduced Size - 4x Head Connection TypeFriction Weld
Head ShapeSquare Rebar ManufacturerCMC Rebar
Head ManufacturerHRC Head FabricatorHRC
Material Standard CodeASTM A706 Headed Bar Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2016-06-07-5-1ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/09/2016Brian
Yes
06/09/2016Bar Broke; OK Necking
2016-06-07-5-2ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/09/2016Brian
Yes
06/09/2016Bar Broke; OK Necking
2016-06-07-5-3ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/09/2016Brian
Yes
06/09/2016Bar Broke; OK Necking
2016-06-07-5-4ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/09/2016Brian
Yes
06/09/2016Bar Broke; OK Necking
2016-06-07-5-5ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/09/2016Brian
Yes
06/09/2016Bar Broke; OK Necking
2016-06-07-5-6ASTM A970-15e1: Standard Specification for Headed Steel Bars for Concrete Reinforcement (Tensile)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/09/2016Brian
Yes
06/09/2016Bar Broke; OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-06-07-5-1 ASTM A970-15e1 (Verified)
DIME Test ID: 2016-06-07-5-2 ASTM A970-15e1 (Verified)
DIME Test ID: 2016-06-07-5-3 ASTM A970-15e1 (Verified)
DIME Test ID: 2016-06-07-5-4 ASTM A970-15e1 (Verified)
DIME Test ID: 2016-06-07-5-5 ASTM A970-15e1 (Verified)
DIME Test ID: 2016-06-07-5-6 ASTM A970-15e1 (Verified)