Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2016-05-26-15

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 7428
DEA: 07215944
EFIS: 0700001834
DIST-CO-RTE-PM07-LA-5-4.0/5.9
Award Date08/23/2012
Closeout Date07/02/2021
Work DescriptionRECONSTRUCT AND WIDEN FREEWAY AND UNDERCROSSING STRUCTURES.
Location DescriptionLOS ANGELES COUNTY IN NORWALK FROM 0.4 MILE SOUTH OF SAN ANTONIO DRIVE UNDERCROSSING TO 0.7 MILE NORTH OF PIONEER BOULEVARD UNDERCROSSING
QA Service Level1 (Verified on 11/07/2012)

Sample Information

Sample Taken Date05/26/2016 Sample Unique Key15
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/03/2016
Sample typeQuality Assurance A brief description of the sampleBarsplice Zap Screwlok Coupler
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byMazen Last name of sampler or witnessed byKabbarx
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameBarSplice Gerdau Transportation Laboratory (TL) NumberNA
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingAuthorization Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerGerdau
Coupler ManufacturerBarSplice Intermediate Assembler or FabricatorUnknown
Rebar Size#9 Coupler ModelZap Screwlok
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)490194 490193 Rebar Heat Number(s)65023754 02
Rebar Size 2 NA Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2016-05-26-15-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory06/03/2016
Yes
06/06/2016Service Splice
2016-05-26-15-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory06/03/2016
Yes
06/06/2016Service Splice
2016-05-26-15-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian Ewing, CT HQ - Sacramento Structural Materials Testing Laboratory06/03/2016
Yes
06/06/2016Service Splice

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-05-26-15-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-05-26-15-2 CTM 670-December 2013 (Verified)