Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2016-06-02-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 208926
DEA: 120F96A4
EFIS: 1200020277
COOP: 120680
DIST-CO-RTE-PM12-ORA-5,96-3.0/3.7
Award Date11/25/2014
Closeout Date01/09/2020
Work DescriptionADD ONE HOV LANE EACH WAY ON ROUTE 5
Location DescriptionSOUTH OF AVENIDA PICO TO SOUTH OF AVENIDA VISTA HERMOSA, IN ORANGE COUNTY
QA Service Level1 (Verified on 01/19/2015)

Sample Information

Sample Taken Date06/02/2016 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/03/2016
Sample typeQuality Assurance A brief description of the sampleBarsplice Griptwist coupler
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byAlex Last name of sampler or witnessed byGordon
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameIntegrity Rebar Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerGerdau
Coupler ManufacturerBarsplice Intermediate Assembler or FabricatorUnknown
Rebar Size#8 Coupler ModelGripTwist
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)A152824, A152547, A153834, A153597 Rebar Heat Number(s)65021930
Rebar Size 2 NA Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2016-06-02-1-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/03/2016
Yes
06/08/2016Service Splice
2016-06-02-1-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/03/2016
Yes
06/08/2016Service Splice
2016-06-02-1-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)Brian, CT HQ - Sacramento Structural Materials Testing Laboratory06/03/2016
Yes
06/08/2016Service Splice

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2016-06-02-1-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-06-02-1-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2016-06-02-1-3 CTM 670-December 2013 (Verified)