Sample Record
Owner Lab
- CT D08 - Fontana Southern Regional Laboratory
DIME Sample ID 2016-04-13-4
Project Information
Project Identifiers | Project ID: 210875 DEA: 07297804 EFIS: 0713000232 |
---|---|
DIST-CO-RTE-PM | 07-LA-138-2.1/36.7 |
Award Date | 12/31/1969 |
Closeout Date | 10/26/2016 |
Work Description | INSTALL RUMBLE STRIPS |
Location Description | NEAR LANCASTER, FROM EAST OF ROUTE 5 TO WEST OF ROUTE 14 |
QA Service Level | 1 (Verified on 10/15/2015) |
Sample Information
Sample Taken Date | 04/13/2016 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/14/2016 |
Sample type | Acceptance | A brief description of the sample | Shoulder Backing |
The quantity of what the sample constitutes | 2 Bags | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Unknown | Last name of sampler or witnessed by | Unknown |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | 6122B | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Pavement Recycling | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Unknown |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
The plant number | Unknown | A detailed description of where the material sample was collected | Unknown |
Where the material sample would have been placed if not sampled | Unknown | Primary Aggregate Nominal Size | |
The concrete mix design number | Lot number | Not set | |
Sublot number | Not set | Aggregate Mix Number | Not set |
Submitted Tests
DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Submitted By | Verified? | Release Date | Test Comments | Actions |
---|---|---|---|---|---|---|---|---|
2016-04-13-4-1 | CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates | MD Shahjahan, CT D08 - Fontana Southern Regional Laboratory | 04/19/2016 | Charles Mcdonald | No | Info | ||
2016-04-13-4-2 | CTM 212-May 2010: Method of Test for Unit Weight of Aggregate | Danilo Ferrer, CT D08 - Fontana Southern Regional Laboratory | 04/26/2016 | Charles Mcdonald | No | Info | ||
2016-04-13-4-3 | CTM 217-June 2011: Method of Test for Sand Equivalent | Nemencio Daof, CT D08 - Fontana Southern Regional Laboratory | 04/21/2016 | Charles Mcdonald | No | Info |
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2016-04-13-4-1 CTM 202-November 2011
DIME Test ID: 2016-04-13-4-2 CTM 212-May 2010
DIME Test ID: 2016-04-13-4-3 CTM 217-June 2011