Sample Record

Owner Lab

  • CT HQ - Sacramento Concrete Testing Laboratory

DIME Sample ID 2015-11-13-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 210390
DEA: 041J7604
EFIS: 0414000349
DIST-CO-RTE-PM04-SOL-80-39.8
Award Date06/17/2015
Closeout Date12/21/2017
Work DescriptionBUILD MATERIALS STORAGE BINS WITH CANOPY.
Location DescriptionSOLANO COUNTY IN DIXON AT THE DIXON MAINTENANCE STATION 8628 SPARLING LANE
QA Service Level1 (Verified on 07/28/2015)

Sample Information

Sample Taken Date11/13/2015 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/16/2015
Sample typeQuality Control A brief description of the sampleconcrete
The quantity of what the sample constitutescylinders From where was the sample collectedJob Site
First name of sampler or witnessed byGarnal Last name of sampler or witnessed byAbushaban
Title of samplerTE Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameunknown Transportation Laboratory (TL) Number209901
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierUnknown
Structure nameUnknown

Material Information

Material TypeConcrete The concrete mix design numberCT072CR5M
The truck number from where the sample was collectedUnknown The batch plant ticket number from where the sample was collectedunknown
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedtruck Where the material sample would have been placed if not sampledGround Floor Slab
From Lot No.Not set Bag Lot No.Not set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2015-11-13-1-1ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensBang, CT HQ - Sacramento Concrete Testing Laboratory11/20/2015Bang Nguyen
Yes
11/20/2015

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2015-11-13-1-1 ASTM C39-17a (Verified)