Sample Record

Owner Lab

  • CT D08 - Fontana Southern Regional Laboratory

DIME Sample ID 2015-10-20-5

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 210307
DEA: 073P7004
EFIS: 0712000437
DIST-CO-RTE-PM07-LA-L5724-
Award Date05/15/2015
Closeout Date05/10/2017
Work DescriptionCONSTRUCT MAINTENANCE STATION
Location DescriptionVENTURA COUNTY IN OJAI AT THE OJAI MAINTENANCE STATION AT 1116 MARICOPA HIGHWAY
QA Service Level1 (Verified on 06/01/2015)

Sample Information

Sample Taken Date10/20/2015 Sample Unique Key5
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/27/2015
Sample typeQuality Control A brief description of the sample6X12
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byA Last name of sampler or witnessed byMAGHSOUDLOO
Title of samplerSR Telephone number of samplerUnknown
Laboratory sample identification921-49 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameASSOCIATED READY MIX Transportation Laboratory (TL) Number053649
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierOJAI MS BLDG
Structure nameUnknown

Material Information

Material TypeConcrete The concrete mix design number55630
The truck number from where the sample was collectedLOAD 2 The batch plant ticket number from where the sample was collectedNP
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedLOAD 2 Where the material sample would have been placed if not sampledUnknown
From Lot No.Not set Bag Lot No.Not set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2015-10-20-5-1ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMatthew Clayton, CT D08 - Fontana Southern Regional Laboratory11/10/2015Matthew Clayton
Yes
11/10/2015
2015-10-20-5-2ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMatthew Clayton, CT D08 - Fontana Southern Regional Laboratory11/17/2015Matthew Clayton
Yes
11/17/2015

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2015-10-20-5-1 ASTM C39-17a (Verified)
DIME Test ID: 2015-10-20-5-2 ASTM C39-17a (Verified)