Sample Record

Owner Lab

  • CT D08 - Fontana Southern Regional Laboratory

DIME Sample ID 2015-08-18-2

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 210484
DEA: 080R8114
EFIS: 0815000105
DIST-CO-RTE-PM08-RIV-215-R15.0
Award Date06/16/2015
Closeout Date12/07/2015
Work DescriptionINSTALL A WEIGH-IN-MOTION (WIM) SYSTEM
Location DescriptionRIVERSIDE COUNTY NEAR MURRIETA AT 0.5 MILE NORTH OF KELLER ROAD.
QA Service Level1 (Verified on 07/21/2015)

Sample Information

Sample Taken Date08/18/2015 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/24/2015
Sample typeQuality Control A brief description of the sample6X12
The quantity of what the sample constitutes2 From where was the sample collectedJob Site
First name of sampler or witnessed byBRIAN Last name of sampler or witnessed byTEH
Title of samplerTE Telephone number of samplerUnknown
Laboratory sample identification919-1 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameJOB Transportation Laboratory (TL) Number1
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierWIM ON 215 BESIDE SCOTT RD
Structure nameI215 LANE 3 PM 15 LCBRS

Material Information

Material TypeConcrete The concrete mix design numberV30LCBRS
The truck number from where the sample was collectedUnknown The batch plant ticket number from where the sample was collectedNP
Concrete batch plantUnknown The fabricator/manufacturer designation for the sampleUnknown
A detailed description of where the material sample was collectedTRUCK Where the material sample would have been placed if not sampledUnknown
From Lot No.Not set Bag Lot No.Not set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2015-08-18-2-1ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMatthew Clayton, CT D08 - Fontana Southern Regional Laboratory08/25/2015Matthew Clayton
Yes
08/25/2015

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2015-08-18-2-1 ASTM C39-17a (Verified)