Sample Record
Owner Lab
- CT D10 - Stockton Field Laboratory
DIME Sample ID 2023-01-06-9
Project Information
Project Identifiers | Project ID: 993493 DEA: 100Q1224 EFIS: 1014000168 |
---|---|
DIST-CO-RTE-PM | 10-MER-99-28.2/R37.3 |
Award Date | 03/30/2022 |
Closeout Date | Not set |
Work Description | WIDEN CONCRETE PAVEMENT LANES AND BRIDGES. |
Location Description | MERCED COUNTY IN AND NEAR LIVINGSTON FROM 0.8 MILE SOUTH OF HAMMATT AVENUE OVERCROSSING TO STANISLAUS COUNTY LINE |
QA Service Level | 1 (Verified on 01/10/2022) |
Sample Information
Sample Taken Date | 01/06/2023 | Sample Unique Key | 9 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/09/2023 |
Sample type | Department Acceptance | A brief description of the sample | 1x4, 3/8" and sand collected |
The quantity of what the sample constitutes | Sufficient | From where was the sample collected | Other |
First name of sampler or witnessed by | Tim | Last name of sampler or witnessed by | Trefz |
Title of sampler | Materials Technician | Telephone number of sampler | 2092518653 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Builders Concrete Plant - Merced | Transportation Laboratory (TL) Number | Cherokee Field Lab 401 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name | Concrete Trial batch |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Teichert Santa Fe Winton |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | Teichert Santa Fe - Winton | The fabricator/manufacturer designation for the sample | Trial Batch Structural Concrete |
The plant number | teichert Winton | A detailed description of where the material sample was collected | Collected from stockpile |
Where the material sample would have been placed if not sampled | Bridge Deck | Primary Aggregate Nominal Size | 1 inch |
The concrete mix design number | ND14505 | Lot number | |
Sublot number | Aggregate Mix Number |
Submitted Tests
DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Submitted By | Verified? | Release Date | Test Comments | Actions |
---|---|---|---|---|---|---|---|---|
No results found. |
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |