Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2022-12-20-36

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 209698
DEA: 072332E4
EFIS: 0700000391
COOP: 0705187
DIST-CO-RTE-PM07-LA-I-5-45.4/54
Award Date07/01/2021
Closeout DateNot set
Work DescriptionAddition of 14 miles of HOV lanes in both directions would extend existing carpool lanes on the I- 5 in San Fernando Valley to Santa Clarita Valley
Location DescriptionThe I-5 North Capacity Enhancements Project focuses on improvements to the I-5 freeway from cities of Santa Clarita and Castaic, beginning at the SR-14 interchange to Parker Rd.
QA Service Level2 (Verified on 02/03/2021)

Sample Information

Sample Taken Date12/20/2022 Sample Unique Key36
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/27/2022
Sample typeQuality Assurance A brief description of the sampleBearing Pad
The quantity of what the sample constitutes10 From where was the sample collectedFabricator
First name of sampler or witnessed byBrad Last name of sampler or witnessed byStreeter
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameScougal Rubber Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM1 - Elastomeric Bearing Pad Mfg. Lot Number(s)22178-3
Material/Compound/Elastomer IDNA Samples Representing10
Description (size)5x22x24 Comments
Description (Number of Shims)10 Type of Bearing PadSteel
Description (Thickness of Shims)14 gage Manufacturer(s)Scougal Rubber
Batch NumberNA

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2022-12-20-36-1SMTL BILST-06: (Neoprene Verification) Bilstein TestYared Melketsadik, CT HQ - Sacramento Chemistry Laboratory01/05/2023Yared Melketsadik
Yes
01/05/2023
2022-12-20-36-2ASTM D412-16r21: Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tensionrmacias, CT HQ - Sacramento Structural Materials Testing Laboratory01/06/2023rmacias
Yes
01/12/2023
2022-12-20-36-3ASTM D624-00r20: Standard Test Method for Tear Strength of Conventional Vulcanized Rubber and Thermoplastic Elastomersr.macias, CT HQ - Sacramento Structural Materials Testing Laboratory01/06/2023r.macias
Yes
01/12/2023
2022-12-20-36-4ASTM D2240-15r21: Standard Test Method for Rubber Property - Durometer HardnessRuben Macias, CT HQ - Sacramento Structural Materials Testing Laboratory01/09/2023Ruben Macias
Yes
01/12/2023Hardness

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2022-12-20-36-1 SMTL BILST-06 (Verified)
DIME Test ID: 2022-12-20-36-2 ASTM D412-16r21 (Verified)
DIME Test ID: 2022-12-20-36-3 ASTM D624-00r20 (Verified)
DIME Test ID: 2022-12-20-36-4 ASTM D2240-15r21 (Verified)