Sample Record

Owner Lab

  • CT D07 - Plant Services

DIME Sample ID 2022-02-24-31

Project Information

Project IdentifiersProject ID: 7613
DEA: 071218W4
EFIS: 0700021119
DIST-CO-RTE-PM07-LA-5-29.4/31.6
Award Date11/29/2012
Closeout Date07/31/2023
Work DescriptionREALIGN ROUTE 5 AND RAILROAD TRACKS AND RECONFIGURE ON- AND OFF-RAMPS.
Location DescriptionLOS ANGELES COUNTY IN BURBANK FROM WEST MAGNOLIA BOULEVARD OVERCROSSING TO 0.3 MILE NORTH OF BUENA VISTA STREET/WINONA AVENUE UNDERCROSSING
QA Service Level1 (Verified on 10/08/2012)

Sample Information

Sample Taken Date02/24/2022 Sample Unique Key31
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing02/28/2022
Sample typeVerification A brief description of the samplePCC agg
The quantity of what the sample constitutes110CY From where was the sample collectedDistributor
First name of sampler or witnessed byLuis Last name of sampler or witnessed byAcosta
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameNational Sun Valley Transportation Laboratory (TL) Number6997
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0021
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedstock pile
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design numbers62578GBRC Lot number
Sublot number Aggregate Mix NumberNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2022-02-24-31-1CTM 226-July 2010: Method of Test for Determination of Moisture Content of Soils and Aggregates by Oven DryingLuis Acosta, CT D07 - Plant Services03/03/2022Luis Acosta
Yes
06/13/2022
2022-02-24-31-2CTM 217-June 2011: Method of Test for Sand EquivalentLuis Acosta, CT D07 - Plant Services03/03/2022Luis Acosta
Yes
06/13/2022
2022-02-24-31-3CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesLuis Acosta, CT D07 - Plant Services03/03/2022Luis Acosta
Yes
06/13/2022
2022-02-24-31-4CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)Luis Acosta, CT D07 - Plant Services03/03/2022Luis Acosta
Yes
06/13/2022
2022-02-24-31-5CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse AggregatesLuis Acosta, CT D07 - Plant Services03/03/2022Luis Acosta
Yes
06/13/2022

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2022-02-24-31-1 CTM 226-July 2010 (Verified)
DIME Test ID: 2022-02-24-31-2 CTM 217-June 2011 (Verified)
DIME Test ID: 2022-02-24-31-3 CTM 202-November 2011 (Verified)
DIME Test ID: 2022-02-24-31-4 CTM 227-December 2014 (Verified)
DIME Test ID: 2022-02-24-31-5 CTM 202-November 2011 (Verified)