Sample Record

Owner Lab

  • RMA Group - Rancho Cordova

DIME Sample ID 2022-03-29-35

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214562
DEA: 040J7104
EFIS: 0414000029
DIST-CO-RTE-PM04-SOL-80-1.8/4.4
Award Date03/17/2020
Closeout Date02/29/2024
Work DescriptionRAISE BRIDGE AND PLACE STRUCTURAL CONCRETE.
Location DescriptionSOLANO COUNTY IN VALLEJO AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 12/03/2019)

Sample Information

Sample Taken Date03/29/2022 Sample Unique Key35
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/29/2022
Sample typeQuality Control A brief description of the sampleConcrete
The quantity of what the sample constitutes100 cy From where was the sample collectedJob Site
First name of sampler or witnessed byJose Last name of sampler or witnessed byMurillo
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSyar Napa Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numberCT072DR8M
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected86002955
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedBent Cap at Tennessee Over Pass Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2022-03-29-35-1CTM 557-June 2020: Method of Test for Temperature of Freshly Mixed Hydraulic Cement ConcreteJOSE MURILLO, RMA Group - Rancho Cordova03/29/2022Mathew Lowrance
Yes
04/14/2022
2022-03-29-35-2ASTM C143-20: Standard Test Method for Slump of Hydraulic-Cement ConcreteJOSE MURILLO, RMA Group - Rancho Cordova03/29/2022Mathew Lowrance
Yes
04/14/2022
2022-03-29-35-3CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersTodd Strait, RMA Group - Rancho Cordova04/04/2022Mathew Lowrance
Yes
04/14/2022
2022-03-29-35-4CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersTodd Strait, RMA Group - Rancho Cordova04/05/2022Mathew Lowrance
Yes
04/14/2022
2022-03-29-35-5CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersTodd Strait, RMA Group - Rancho Cordova04/08/2022Mathew Lowrance
Yes
04/14/2022
2022-03-29-35-6CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete CylindersTodd Strait, RMA Group - Rancho Cordova04/26/2022Mathew Lowrance
Yes
04/28/2022

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2022-03-29-35-1 CTM 557-June 2020 (Verified)
DIME Test ID: 2022-03-29-35-2 ASTM C143-20 (Verified)
DIME Test ID: 2022-03-29-35-3 CTM 521-June 2020 (Verified)
DIME Test ID: 2022-03-29-35-4 CTM 521-June 2020 (Verified)
DIME Test ID: 2022-03-29-35-5 CTM 521-June 2020 (Verified)