Sample Record
Owner Lab
- CT HQ - QASI Bay Area Field Office
DIME Sample ID 2014-08-27-12
Project Information
Project Identifiers | Project ID: 209247 DEA: 024E6304 EFIS: 0212000010 |
---|---|
DIST-CO-RTE-PM | 02-SIS-96-56.0 |
Award Date | 04/08/2014 |
Closeout Date | 01/10/2017 |
Work Description | FISH PASSAGE - REPLACE CULVERT WITH BRIDGE |
Location Description | SISKIYOU COUNTY NEAR SEIAD VALLEY AT 3.5 MILES EAST OF THOMPSON CREEK BRIDGE |
QA Service Level | 1 (Verified on 04/07/2014) |
Sample Information
Sample Taken Date | 08/27/2014 | Sample Unique Key | 12 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/29/2014 |
Sample type | Informational | A brief description of the sample | Abutment |
The quantity of what the sample constitutes | 2 | From where was the sample collected | Source |
First name of sampler or witnessed by | Simion | Last name of sampler or witnessed by | Ramirez |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | 0 |
The fabricator/manufacturer/facility name | KieCon | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Unknown | |
Structure name | Unknown |
Material Information
Material Type | Concrete | The concrete mix design number | K4070442 |
---|---|---|---|
The truck number from where the sample was collected | Unknown | The batch plant ticket number from where the sample was collected | 711771 |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
A detailed description of where the material sample was collected | source | Where the material sample would have been placed if not sampled | Not set |
From Lot No. | Not set | Bag Lot No. | Not set |
Submitted Tests
DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Submitted By | Verified? | Release Date | Test Comments | Actions |
---|---|---|---|---|---|---|---|---|
2014-08-27-12-1 | ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens | William Sommer, CT HQ - QASI Bay Area Field Office | 09/24/2014 | William Sommer | No | Info |
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2014-08-27-12-1 ASTM C39-10