Sample Record

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

DIME Sample ID 2021-09-17-7

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 215425
DEA: 06360244
EFIS: 0613000005
DIST-CO-RTE-PM06-TUL-99-30.6/35.2
Award Date04/23/2021
Closeout DateNot set
Work DescriptionWiden Freeway & Bridge Construction (Concrete Bridge)
Location DescriptionNot set
QA Service Level1 (Verified on 11/01/2021)

Sample Information

Sample Taken Date09/17/2021 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/27/2021
Sample typeQuality Assurance A brief description of the sample#5 x 1'-7" dia.
The quantity of what the sample constitutes8 hoops from lot 1-2 From where was the sample collectedFabricator
First name of sampler or witnessed byOsiel Last name of sampler or witnessed byRamirez
Title of sampler Telephone number of sampler5599740870
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTNT Rebar Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL123-100-21 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)4110884
Hoop Manufacturer Lot Number(s)Lot 1-2 Material Standard CodeASTM A706
Material Grade60 Rebar Size#5
Diameter of Hoop1'-7" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC Steel Arizona
Welding CompanyTNT Rebar Company Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2021-09-17-7-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory09/27/2021fsaylor
Yes
09/28/2021OK Necking
2021-09-17-7-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory09/27/2021fsaylor
Yes
09/28/2021OK Necking
2021-09-17-7-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory09/27/2021fsaylor
Yes
09/28/2021OK Necking
2021-09-17-7-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory09/27/2021fsaylor
Yes
09/28/2021OK Necking
2021-09-17-7-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory09/27/2021fsaylor
Yes
09/28/2021OK Necking
2021-09-17-7-6CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory09/27/2021fsaylor
Yes
09/28/2021Broke At Weld OK Necking
2021-09-17-7-7CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory09/27/2021fsaylor
Yes
09/28/2021OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-09-17-7-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-09-17-7-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-09-17-7-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-09-17-7-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-09-17-7-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-09-17-7-6 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-09-17-7-7 CTM 670-December 2013 (Verified)