Sample Record
Owner Lab
- Leighton Consulting, Incorporated - San Diego
DIME Sample ID 2014-08-14-8
Project Information
Project Identifiers | Project ID: 7780 DEA: 112T1824 EFIS: 1100020051 |
---|---|
DIST-CO-RTE-PM | 11-SD-805-4.7/5.6 |
Award Date | 01/03/2013 |
Closeout Date | 09/07/2018 |
Work Description | REPLACE STRUCTURE AND CONSTRUCT DIRECT ACCESS RAMP (DAR). |
Location Description | SAN DIEGO COUNTY IN CHULA VISTA FROM 0.4 MILE SOUTH OF EAST PALOMAR STREET OVERCROSSING TO 0.1 MILE NORTH OF NAPLES STREET UNDERCROSSING |
QA Service Level | 1 (Verified on 12/10/2012) |
Sample Information
Sample Taken Date | 08/14/2014 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/15/2014 |
Sample type | Verification | A brief description of the sample | concrete cylinders |
The quantity of what the sample constitutes | 13 cylinders | From where was the sample collected | Other |
First name of sampler or witnessed by | Aston | Last name of sampler or witnessed by | James |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | Not set | |
The fabricator/manufacturer/facility name | jobsite | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | 104009F |
---|---|---|---|
The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 125670 | |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | Palomar Bridge Deck easterly third of deck | Where the material sample would have been placed if not sampled | Not set |
From Lot No. | Not set | Bag Lot No. | Not set |
Submitted Tests
DIME Test ID | Test Method | Tester Name, Testing Lab | Date Tested | Submitted By | Verified? | Release Date | Test Comments | Actions |
---|---|---|---|---|---|---|---|---|
2014-08-14-8-1 | ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens | Matt Vinet, Leighton Consulting, Incorporated - San Diego | 08/17/2014 | Matt Vinet | Yes | 08/26/2014 | ||
2014-08-14-8-2 | ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens | Matt Vinet, Leighton Consulting, Incorporated - San Diego | 08/19/2014 | Matt Vinet | Yes | 08/26/2014 | ||
2014-08-14-8-3 | ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens | Matt Vinet, Leighton Consulting, Incorporated - San Diego | 08/21/2014 | Matt Vinet | Yes | 08/26/2014 | ||
2014-08-14-8-4 | ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens | Frank Mina, Leighton Consulting, Incorporated - San Diego | 08/22/2014 | Frank Mina | Yes | 08/26/2014 | ||
2014-08-14-8-5 | ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens | Frank Mina, Leighton Consulting, Incorporated - San Diego | 08/24/2014 | Frank Mina | Yes | 08/26/2014 | ||
2014-08-14-8-6 | ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens | Frank Mina, Leighton Consulting, Incorporated - San Diego | 08/26/2014 | Frank Mina | Yes | 08/26/2014 | ||
2014-08-14-8-7 | ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens | Frank Mina, Leighton Consulting, Incorporated - San Diego | 08/28/2014 | Frank Mina | No | Info | ||
2014-08-14-8-8 | ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens | Frank Mina, Leighton Consulting, Incorporated - San Diego | 09/11/2014 | Frank Mina | No | Info |
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2014-08-14-8-1 ASTM C39-10 (Verified)
DIME Test ID: 2014-08-14-8-2 ASTM C39-10 (Verified)
DIME Test ID: 2014-08-14-8-3 ASTM C39-10 (Verified)
DIME Test ID: 2014-08-14-8-4 ASTM C39-10 (Verified)
DIME Test ID: 2014-08-14-8-5 ASTM C39-10 (Verified)
DIME Test ID: 2014-08-14-8-6 ASTM C39-10 (Verified)
DIME Test ID: 2014-08-14-8-7 ASTM C39-10
DIME Test ID: 2014-08-14-8-8 ASTM C39-10