Sample Record
Owner Lab
- CT HQ - QASI Sacramento Field Office
DIME Sample ID 2021-09-10-5
Sample is locked from editing. info
Project Information
Project Identifiers | Project ID: 214099 DEA: 024F5904 EFIS: 0213000010 |
---|---|
DIST-CO-RTE-PM | 02-TEH-5-R25.4 |
Award Date | 07/08/2020 |
Closeout Date | 08/14/2023 |
Work Description | BRIDGE SEISMIC RETROFIT AND SCOUR REPAIR. |
Location Description | TEHAMA COUNTY IN RED BLUFF AT SACRAMENTO RIVER BRIDGE |
QA Service Level | 1 (Verified on 05/07/2019) |
Sample Information
Sample Taken Date | 09/10/2021 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/13/2021 |
Sample type | Department Acceptance | A brief description of the sample | 1-8 x 3 1/2 A325 Hex Bolt HDG |
The quantity of what the sample constitutes | 56 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Sherri | Last name of sampler or witnessed by | Brannon |
Title of sampler | QA Inspector | Telephone number of sampler | 916-826-6371 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | CandK Johnson Ind | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B22-086-21 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | 431124A |
---|---|---|---|
Heat Number(s) | 100100668 | Nut Mfg. Lot Number(s) | 455386C |
Washer Mfg. Lot Number(s) | D8310 | Bolt Specification | ASTM A325 |
Bolt Length(s) | 4 1/2 inches | Nut Specification | ASTM A563 |
Washer Specification | ASTM F436 | Finish | HDG |
Diameter/Size | 1 inch | Bolt Mfg. Lot Number | 431124A |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Submitted Tests
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2021-09-10-5-1 ASTM F606-14a (Verified)
DIME Test ID: 2021-09-10-5-2 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-09-10-5-3 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-09-10-5-4 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-09-10-5-5 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-09-10-5-6 ASTM B499-14 (Verified)
DIME Test ID: 2021-09-10-5-7 ASTM B499-14 (Verified)
DIME Test ID: 2021-09-10-5-8 ASTM B499-14 (Verified)
DIME Test ID: 2021-09-10-5-9 ASTM B499-14 (Verified)
DIME Test ID: 2021-09-10-5-10 ASTM B499-14 (Verified)
DIME Test ID: 2021-09-10-5-11 ASTM E18-15 (Verified)