Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2021-08-31-8

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 214995
DEA: 040J5304
EFIS: 0414000010
DIST-CO-RTE-PM04-ALA-880-11.4/12.2
Award Date01/04/2021
Closeout Date04/26/2023
Work DescriptionPATTERSON SLOUGH BRIDGE DECK REHAB
Location DescriptionALAMEDA COUNTY IN FREMONT FROM 0.4 MILE SOUTH TO 0.4 MILE NORTH OF PATTERSON SLOUGH BRIDGE
QA Service Level1 (Verified on 10/19/2020)

Sample Information

Sample Taken Date08/31/2021 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/03/2021
Sample typeQuality Assurance A brief description of the sampleD250L Bar Lock Coupler
The quantity of what the sample constitutes8 From where was the sample collectedFabricator
First name of sampler or witnessed byKevin Last name of sampler or witnessed byCarpenter
Title of samplerQA Telephone number of sampler14156081742
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameDayton Superior Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB24-070-21 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCascade
Coupler ManufacturerDayton Intermediate Assembler or Fabricator
Rebar Size#6 Coupler Model250DL
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)A180950 Rebar Heat Number(s)091421
Rebar Size 2 6 Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2021-08-31-8-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory09/02/2021fsaylor
Yes
09/07/2021Service Splice
2021-08-31-8-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory09/02/2021fsaylor
Yes
09/07/2021Service Splice
2021-08-31-8-3THIS TEST HAS BEEN SUPERSEDED.
CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
<None>, CT HQ - Sacramento Structural Materials Testing Laboratory09/02/2021<None>
Yes
09/07/2021THIS TEST HAS BEEN SUPERSEDED.
2021-08-31-8-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory09/02/2021fsaylor
Yes
09/07/2021Service Splice

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-08-31-8-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-08-31-8-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-08-31-8-3 CTM 670-December 2013 (Verified)