Sample Record

Owner Lab

  • CT HQ - QASI Los Angeles Field Office

DIME Sample ID 2021-08-06-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 215093
DEA: 101C2804
EFIS: 1014000134
DIST-CO-RTE-PM10-SJ-99-30.9/31.3
Award Date10/21/2020
Closeout Date08/30/2023
Work DescriptionRAISED BRIDGES, REALIGN RAMPS AND CONSTRUCT AUXILIARY LANE.
Location DescriptionSAN JOAQUIN COUNTY IN LODI FROM 0.4 MILE SOUTH OF ROUTE 12/99 SEPARATION TO 0.3 MILE SOUTH OF TURNER ROAD OVERCROSSING
QA Service Level1 (Verified on 08/21/2020)

Sample Information

Sample Taken Date08/06/2021 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/11/2021
Sample typeQuality Assurance A brief description of the sampleASTM A706 GR 60 #5 2'-0"
The quantity of what the sample constitutes8 From where was the sample collectedOther
First name of sampler or witnessed byArthur Last name of sampler or witnessed byPeterson
Title of samplerQA Telephone number of sampler7073428602
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameRKR Steel Welding Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL110-112-21 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)084021
Hoop Manufacturer Lot Number(s)Lot 1 and 2 Material Standard CodeASTM A706
Material Grade60 Rebar Size#5
Diameter of Hoop2'-0" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCascade Steel
Welding CompanyRKR Steel Welding Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2021-08-06-1-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/12/2021fsaylor
Yes
08/12/2021OK Necking
2021-08-06-1-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/12/2021fsaylor
Yes
08/12/2021OK Necking
2021-08-06-1-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/12/2021fsaylor
Yes
08/12/2021OK Necking
2021-08-06-1-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/12/2021fsaylor
Yes
08/12/2021OK Necking
2021-08-06-1-5CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/12/2021fsaylor
Yes
08/12/2021OK Necking
2021-08-06-1-6CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory08/12/2021fsaylor
Yes
08/12/2021OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-08-06-1-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-08-06-1-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-08-06-1-3 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-08-06-1-4 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-08-06-1-5 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-08-06-1-6 CTM 670-December 2013 (Verified)