Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2021-07-29-3

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 215062
DEA: 030F2904
EFIS: 0314000101
DIST-CO-RTE-PM03-BUT-99-14.9/15.7
Award Date09/24/2020
Closeout Date03/02/2022
Work DescriptionCONSTRUCT BRIDGE AND ROADWAY; & REMOVE BRIDGE.
Location DescriptionBUTTE COUNTY ABOUT 10 MILES NORTH OF GRIDLEY FROM 0.3 MILE SOUTH TO 0.5 MILE NORTH OF NELSON AVENUE
QA Service Level1 (Verified on 07/20/2020)

Sample Information

Sample Taken Date07/29/2021 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/29/2021
Sample typeQuality Assurance A brief description of the sample#10 HRC 500/510 Couplers
The quantity of what the sample constitutes200 Couplers From where was the sample collectedJob Site
First name of sampler or witnessed byEd Last name of sampler or witnessed byEricson
Title of samplerASR Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameMCM Construction Transportation Laboratory (TL) NumberC631503
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerHRC Intermediate Assembler or Fabricator
Rebar Size#10 Coupler ModelHRC 500/510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)73118523 73118000 Rebar Heat Number(s)3500014904
Rebar Size 2 Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2021-07-29-3-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory07/29/2021fsaylor
Yes
08/02/2021Ok Necking
2021-07-29-3-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory07/29/2021fsaylor
Yes
08/02/2021Ok Necking
2021-07-29-3-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory07/29/2021fsaylor
Yes
08/02/2021Ok Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-07-29-3-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-07-29-3-2 CTM 670-December 2013 (Verified)