Sample Record

Owner Lab

  • CT HQ - QASI Sacramento Field Office

DIME Sample ID 2021-07-22-4

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 215231
DEA: 042A3324
EFIS: 0414000039
DIST-CO-RTE-PM04-ALA-84-10.8/18
Award Date02/22/2021
Closeout Date02/29/2024
Work DescriptionNILES CANYON SAFETY PROJECT
Location DescriptionALAMEDA CREEK BR OH (33-0034) BRIDGE RAIL REPLACEMENT, 2,060 LF; AND STONYBROOK CREEK BRIDGE (SLAB BRIDGE)
QA Service Level1 (Verified on 10/19/2020)

Sample Information

Sample Taken Date07/22/2021 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/23/2021
Sample typeQuality Assurance A brief description of the sample#6 with A2 Lenton Couplers
The quantity of what the sample constitutes150 From where was the sample collectedFabricator
First name of sampler or witnessed bySherri Last name of sampler or witnessed byBrannon
Title of samplerCA METS QA Inspector Telephone number of sampler916-826-6371
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameC and N Reinforcing Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB22-059-21 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerErico Intermediate Assembler or Fabricator
Rebar Size#6 Coupler ModelA2 Lenton Couplersx
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)L9760 Rebar Heat Number(s)3500018139
Rebar Size 2 6 Coupler Unique IDNot set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2021-07-22-4-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory07/28/2021fsaylor
Yes
07/28/2021Servce Splice
2021-07-22-4-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory07/28/2021fsaylor
Yes
07/28/2021Servce Splice
2021-07-22-4-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory07/28/2021fsaylor
Yes
07/28/2021

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-07-22-4-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-07-22-4-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-07-22-4-3 CTM 670-December 2013 (Verified)