Sample Record

Owner Lab

  • Leighton Consulting, Incorporated - San Diego

DIME Sample ID 2014-03-12-4350809

Project Information

Project IdentifiersProject ID: 7780
DEA: 112T1824
EFIS: 1100020051
DIST-CO-RTE-PM11-SD-805-4.7/5.6
Award Date01/03/2013
Closeout Date09/07/2018
Work DescriptionREPLACE STRUCTURE AND CONSTRUCT DIRECT ACCESS RAMP (DAR).
Location DescriptionSAN DIEGO COUNTY IN CHULA VISTA FROM 0.4 MILE SOUTH OF EAST PALOMAR STREET OVERCROSSING TO 0.1 MILE NORTH OF NAPLES STREET UNDERCROSSING
QA Service Level1 (Verified on 12/10/2012)

Sample Information

Sample Taken Date03/12/2014 Sample Unique Key4350809
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing03/14/2014
Sample typeVerification A brief description of the sampleconcrete cylinders
The quantity of what the sample constitutes4 cylinders From where was the sample collectedOther
First name of sampler or witnessed byAston Last name of sampler or witnessed byJames
Title of samplerNot set Telephone number of samplerNot set
Laboratory sample identificationNot set Linked DIME Sample IDNot set
The fabricator/manufacturer/facility nameJobsite Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeConcrete The concrete mix design number104009F
The truck number from where the sample was collected328 The batch plant ticket number from where the sample was collected105970
Concrete batch plantNot set The fabricator/manufacturer designation for the sampleNot set
A detailed description of where the material sample was collectedChute Where the material sample would have been placed if not sampledBridge Soffit southwest side
From Lot No.Not set Bag Lot No.Not set

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2014-03-12-4350809-1ASTM C1064-08: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement ConcreteAston James, Leighton Consulting, Incorporated - San Diego03/12/2014Aston James
Yes
07/08/2014
2014-03-12-4350809-2ASTM C143-10a: Standard Test Method for Slump of Hydraulic-Cement ConcreteAston James, Leighton Consulting, Incorporated - San Diego03/12/2014Aston James
Yes
07/08/2014
2014-03-12-4350809-3ASTM C231-10: Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure MethodAston James, Leighton Consulting, Incorporated - San Diego03/12/2014Aston James
Yes
07/08/2014
2014-03-12-4350809-4ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMatt Vinet, Leighton Consulting, Incorporated - San Diego03/19/2014Matt Vinet
Yes
07/08/2014Design strength 4000 psi at 28 days
2014-03-12-4350809-5ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete SpecimensMatt Vinet, Leighton Consulting, Incorporated - San Diego04/09/2014Matt Vinet
Yes
07/08/2014

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2014-03-12-4350809-1 ASTM C1064-08 (Verified)
DIME Test ID: 2014-03-12-4350809-2 ASTM C143-10a (Verified)
DIME Test ID: 2014-03-12-4350809-3 ASTM C231-10 (Verified)
DIME Test ID: 2014-03-12-4350809-4 ASTM C39-10 (Verified)