Sample Record
Owner Lab
- CT HQ - QASI Los Angeles Field Office
DIME Sample ID 2021-06-29-3
Project Information
Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 06/29/2021 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 07/06/2021 |
Sample type | Quality Assurance | A brief description of the sample | 1"-8 |
The quantity of what the sample constitutes | 16 Samples out of 24,300 pcs. | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Rigoberto | Last name of sampler or witnessed by | Marin |
Title of sampler | AMR | Telephone number of sampler | 951-500-0685 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Blue Circle | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L133-078-21 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | Gerdau Steel 5804640003 | Nut Mfg. Lot Number(s) | 34659-5804640003 |
Washer Mfg. Lot Number(s) | N/A | Bolt Specification | N/A |
Bolt Length(s) | N/A | Nut Specification | ASTM A563 |
Washer Specification | N/A | Finish | ASTM A563 |
Diameter/Size | 1"-8 | Bolt Mfg. Lot Number | N/A |
Rocap Test Requirement(s) | Unknown | Lubricant Requirements(s) | Unknown |
Submitted Tests
Go to page:
Sample File Attachments
File Name | Extension | Date Uploaded | Actions |
---|---|---|---|
No results found. |
Test File Attachments
DIME Test ID: 2021-06-29-3-1 ASTM F606-14a (Verified)
DIME Test ID: 2021-06-29-3-2 ASTM F606-14a (Verified)
DIME Test ID: 2021-06-29-3-3 ASTM F606-14a (Verified)
DIME Test ID: 2021-06-29-3-4 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-06-29-3-5 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-06-29-3-6 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-06-29-3-7 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-06-29-3-8 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-06-29-3-9 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-06-29-3-10 ASME B1.2-83r01 (Verified)
DIME Test ID: 2021-06-29-3-11 ASTM B499-14 (Verified)
DIME Test ID: 2021-06-29-3-12 ASTM B499-14 (Verified)
DIME Test ID: 2021-06-29-3-13 ASTM B499-14 (Verified)
DIME Test ID: 2021-06-29-3-14 ASTM B499-14 (Verified)
DIME Test ID: 2021-06-29-3-15 ASTM B499-14 (Verified)
DIME Test ID: 2021-06-29-3-16 ASTM B499-14 (Verified)
DIME Test ID: 2021-06-29-3-17 ASTM B499-14 (Verified)