Sample Record

Owner Lab

  • CT HQ - Sacramento Structural Materials Testing Laboratory

DIME Sample ID 2021-05-27-1

Sample is locked from editing. info

Project Information

Project IdentifiersProject ID: 213747
DEA: 080Q9104
EFIS: 0800020580
DIST-CO-RTE-PM08-SBD-10-R23.8
Award Date01/30/2019
Closeout Date07/27/2022
Work DescriptionRETROFIT BRIDGE PIER WALLS, FOOTINGS AND POLYESTER CONCRETE OVERLAY.
Location DescriptionSAN BERNARDINO COUNTY IN COLTON AT THE SANTA ANA RIVER BRIDGES
QA Service Level1 (Verified on 03/18/2019)

Sample Information

Sample Taken Date05/27/2021 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/28/2021
Sample typeRetest A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutesLot 1 RETEST 150 Total From where was the sample collectedFabricator
First name of sampler or witnessed byDavid Last name of sampler or witnessed byWeeks
Title of samplerASI Telephone number of sampler310-883-8369
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameRKR Steel Welding Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL79-024-21 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)1202017783
Hoop Manufacturer Lot Number(s)Lot 1 RETEST Material Standard CodeASTM A706
Material Grade60 Rebar Size#8
Diameter of Hoop3'-4" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerNucor Utah
Welding CompanyRKR Steel Welding Coating StandardsUncoated
Weld TypeFlash Welded

Submitted Tests

DIME Test IDTest MethodTester Name, Testing LabDate TestedSubmitted ByVerified?Release DateTest CommentsActions
2021-05-27-1-1CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory06/01/2021fsaylor
Yes
06/01/2021OK Necking
2021-05-27-1-2CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory06/01/2021fsaylor
Yes
06/01/2021OK Necking
2021-05-27-1-3CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory06/01/2021fsaylor
Yes
06/01/2021OK Necking
2021-05-27-1-4CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)fsaylor, CT HQ - Sacramento Structural Materials Testing Laboratory06/01/2021fsaylor
Yes
06/01/2021OK Necking

Sample File Attachments

File NameExtensionDate UploadedActions
No results found.

Test File Attachments


DIME Test ID: 2021-05-27-1-1 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-05-27-1-2 CTM 670-December 2013 (Verified)
DIME Test ID: 2021-05-27-1-3 CTM 670-December 2013 (Verified)